6.6 Connections & Setup with EVO
TM
Products
Refer to Section 4 for a description of features and benefits when using the EVO-30AB
in the following configurations.
• With
Remote Display
• With an EVO
TM
Inverter/Charger and a Remote Display
• With an EVO
TM
Inverter/Charger and no Display
6.6.1 Remote Display – EVO-RC-PLUS (Option)
1. Set the DIP switch on the EVO-30AB. Settings are provided on unit or found
in Section 4.
2. Install the EVO-30AB as described in Section 6.1 to 6.3 of this manual.
3. Install the EVO-RC-PLUS in accordance with the EVO-RC-PLUS manual.
4. Connect the communications cable between the Charge Controller and the
EVO-RC-PLUS as shown in the Figure 6.3.
Solar Panel
EQUALIZATION
Push & Hold 5 sec: Start
Push & Hold 2 sec: Stop
PV+
PV –
BAT+
BAT–
BTS+
BTS –
Bulk/Absorption
Float
Equalization
Temp Fault
Fault
STATUS
Model
EVO-30AB
PWM Solar
Charge Controller
EVO-30AB
Fault
RJ45 Comms Cable
(with RC-PLUS)
1 2 3 4 5
ON
DIP
INVER
TER
CHARGER
RC-PLUS
Hold to
Reset Ah
EVO-30AB
Communication
Connection
EVO-RC-PLUS
+
–
32V, 35A Fuse
within 7” of
b
terminal
Battery Temperature Sensor
Fig. 6.3 EVO-30AB with EVO-RC-PLUS Wiring Diagram
SECTION 6 |
INSTALLATION & SETUP