40 | SAMLEX AMERICA INC.
6.6.2 EVO-30AB with EVO
TM
Inverter/Charger and EVO-RC-PLUS
Installing the EVO-30AB Charge Controller, an EVO-RC-PLUS, and an EVO
TM
Inverter/
Charger makes your complete power system manageable from one monitoring device.
The EVO-RC-PLUS will display alarms and status for both the EVO-30AB and the EVO
TM
Inverter/Charger.
1. Install and turn on the EVO
TM
Inverter/Charger in accordance with the EVO
TM
manual.
2. Set the DIP switch on the EVO-30AB. Settings are provided on unit or found
in Section 4.
3. Install the EVO-30AB as described in Section 6.1 to 6.3 of this manual, but
making the battery connection to the “External DC Charger connection on
the EVO
TM
Inverter/Charger. See Fig 6.4 below.
4. Install the EVO-RC-PLUS in accordance with the EVO-RC-PLUS manual.
5. Connect the communications cable between the EVO
TM
Inverter/Charger to
the EVO-30AB as shown in the Figure 6.4 below.
6. Connect the communications cable between the Charge Controller and the
EVO-RC-PLUS as shown in Figure 6.4 below.
Solar Panel
EQUALIZATION
Push & Hold 5 sec: Start
Push & Hold 2 sec: Stop
PV+
PV –
BAT+
BAT–
BTS+
BTS –
Bulk/Absorption
Float
Equalization
Temp Fault
Fault
STATUS
Model
EVO-30AB
PWM Solar
Charge Controller
EVO-30AB
Fault
1 2 3 4 5
ON
DIP
INVER
TER
CHARGER
RC-PLUS
Hold to
Reset Ah
EVO-30AB
Communication
Connection
EVO-RC-PLUS
Battery
EVO
TM
Inverter/Charger
(EVO-1212F shown)
RJ45 Comms
Cable
(with RC-PLUS)
RJ45 Comms
Cable: Included
with EVO-30AB
Fig 6.4 EVO-30AB with EVO-RC-PLUS and EVO
TM
Inverter/Charger Wiring Diagram
SECTION 6 |
INSTALLATION & SETUP
Summary of Contents for EVO-30AB
Page 46: ...46 SAMLEX AMERICA INC Notes ...
Page 47: ...SAMLEX AMERICA INC 47 Notes ...