TRANSFER CHARACTERISTICS
Transfer Relay Type and Capacity
SPDT, 30A
Transfer Time – Inverter to Grid /
Generator
< 1 ms (Synchronized transfer at zero crossing)
Transfer Time – Grid / Generator
to Inverter
Up to 18ms (Synchronized transfer at zero crossing)
INTERNAL BATTERY CHARGER SECTION
AC Input Voltage Range
120 VAC (60 to 140 VAC +/-5% selectable) ; 60 Hz
Max Continuous AC Input Current
11.2A, AC
(At BULK CURRENT = 60 ADC)
11.2A, AC
(At BULK CURRENT = 40 ADC)
AC Input Power Factor (PF)
> 0.95
Programmable Bulk Charging
Current
0 - 60A, DC
0 - 40A, DC
Programmable Charging Voltages :
Bulk / Absorption Stage
Float Stage
Equalization Stage
13.5 to 16.0V (Default 14.4V)
13.0 to 15.0V (Default 13.5V)
14.0 to 16.0V (Default 14.4V)
27.0 to 32.0V (Default 28.8V)
26.0V to 30.0V (Default 27.0V
28.0 to 32.0V (Default 28.8V)
Charger Efficiency
75%
86%
Programmable Charging Profiles
3 profiles under 3-Stage Charging: Bulk, Absorption, Float
1 profile under 4-Stage Charging: Bulk, Absorption, Equalize, Float
2 profiles under 2-Stage Charging: Bulk, Absorption
Battery Temperature Compensation
Battery Temperature Sensor EVO-BTCS included
Compensation Range from -20° C to 60° C
EXTERNAL BATTERY CHARGER SECTION (Solar Charge Controller)
Charging Voltage Range
13 - 16 VDC
26 - 32 VDC
Maximum Charging Current
50A
COOLING, PROTECTIONS AND ALARMS
Cooling
2 Fans – Temperature Controlled, Variable Speed
Protections and Alarms
Battery Low Voltage Alarm and Low / Over Voltage Shut Down
Shut Down under Input Over Current, Output Over Current, Output Over-
load and Output Short
Transformer and Heat Sink Overheat Shut Down
Immunity Against Conducted Electrical Transients in Vehicles