56 | SAMLEX AMERICA INC.
• The Grounding Bus Bar (G-B) in the Electrical Panel of the RV / vehicle is bonded to the
RV / Vehicle Chassis Ground. When the RV / vehicle is connected to the Grid through
the Grid Power Inlet and Cord, the RV / Vehicle Chassis Ground gets bonded to the
Earth Ground of the premises through the Grounding Electrode (GE) / “Ground Rod” of
the premises of the Grid Power System supplying the RV / Vehicle .
(b)
AC Output Grounding:
The metal chassis of AC load(s) gets bonded to (i) the RV /
Vehicle Chassis Ground when not connected to Grid Power and (ii) to the Grounding
Electrode (GE) / Ground Rod of the Grid Power System of the premises when connected to
Grid Power through the Grid Power Supply Cord as follows:
• The metal chassis of the AC load(s) is connected to the Grounding socket (G) of the
GFCI outlet (10) in EVO
TM
through the Grounding Conductor of the load connection
• Grounding socket (G) of GFCI outlet “10” in EVO
TM
is connected to the metal chassis of EVO
TM
.
• The metal chassis of EVO
TM
is connected to the Grounding Pin (G) of the AC Power Inlet
Plug (9)
• The grounding Pin (G) of the AC Power Inlet (9) gets connected to the Grounding Bus
Bar (G-B) in the Electrical Panel of the RV / vehicle through the grounding wire of AC
input connection.
• The Grounding Bus Bar (G-B) in the Electrical Panel of the RV / vehicle is bonded to the
RV / Vehicle Chassis Ground. When the RV / vehicle is connected to the Grid through
the Grid Power Inlet and Cord, the RV / Vehicle Chassis Ground gets bonded to the
Earth Ground of the premises through the Grounding Electrode (GE) / “Ground Rod” of
the premises of the Grid Power System supplying the RV / Vehicle
3.14.3.2 EVO-1212F-HW and EVO-1224F-HW:
Refer to the Installation Diagram for Typical RV / Mobile Installation for EVO-1212F-HW and
EVO-1224F-HW at Fig 3.15.
(a)
AC Input Grounding:
The metal chassis of EVO
TM
gets bonded to (i) the RV / Vehicle
Chassis Ground when not connected to Grid Power and (ii) to the Grounding Electrode
(GE) / Ground Rod of the Grid Power System of the premises when connected to Grid
Power through the Grid Power Supply Cord as follows:
• The metal chassis of EVO
TM
is connected to the “INPUT GND” Terminal (23) of the AC
Input / Output Terminal Block (20) in EVO
TM
• The “INPUT GND” Terminal (23) of the AC Input / Output Terminal Block (20) in
EVO
TM
gets connected to the Grounding Bus Bar (G-B) in the Electrical Panel of the RV
through the grounding wire of AC input connection
• The Grounding Bus Bar (G-B) in the Electrical Panel of the RV / vehicle is bonded to the
RV / Vehicle Chassis Ground. When the RV / vehicle is connected to the Grid through
the Grid Power Inlet and Cord, the RV / Vehicle Chassis Ground gets bonded to the
Earth Ground of the premises through the Grounding Electrode (GE) / “Ground Rod” of
the premises of the Grid Power System supplying the RV / Vehicle
(b)
AC Output Grounding:
The metal chassis of the AC load(s) gets bonded to (i) the RV
/ Vehicle Chassis Ground when not connected to Grid Power and (ii) to the Grounding
Electrode (GE) / Ground Rod of the Grid Power System of the premises when connected to
Grid Power through the Grid Power Supply Cord as follows:
SECTION 3 |
Installation
Summary of Contents for Evolution EVO-1212F
Page 109: ...SAMLEX AMERICA INC 109 Notes...
Page 110: ...110 SAMLEX AMERICA INC Notes...
Page 111: ...SAMLEX AMERICA INC 111 Notes...