46
10.4
Disassembly/Re-assembly operation
10.4.1
Dismantle the FPro G
Unscrew the projector
Objectives
Procedure to be carried out within the framework of maintenance.
Reminder: Assembly errors
The use of improper replacement or defective parts may result in
hazards to personnel, damage, malfunction or general shutdown of
the equipment.
Intervening staff
Qualified personnel.
Prerequisite
Before cleaning or disassembling any component of the
equipment, it is imperative that:
-
To cut off the compressed air supply,
-
Decompress the hoses by pulling the trigger.
Summary of Contents for FPro G
Page 27: ...27 4 4 2 Visuals of the marking elements FPro G CONV FPro G LP FPro G GSP...
Page 55: ...55 Step 13 Raising the trigger Step 14 Feed in air and product...
Page 56: ...56 10 4 3 Replace air valve Step 1 Loosen the nut...
Page 60: ...60 Step 9 Back up The greased needle The needle spring The needle stop Tighten the nut...
Page 65: ...65 Step 1 To remove the hose apply pressure from top to bottom on the arrowed element...
Page 74: ...74 Step 3 Install the new anti drip membrane Step 4 Screw on the gravity cup by hand...