Sirius 800 Series User Manual
Sirius 850 Frame Overview
Product Overview 3.10
Iss 5 Rev 7
Page 41
© 2017 SAM
3.10.2 Signal Flow Through the Router
The Sirius 850 routes video and/or audio signals by using the video and audio crosspoint
modules. The Sirius 850 can be fitted with Multiviewer outputs and Input/Output monitoring as
required (Figure 16). Full details of the options are shown sections 13.4.1, 13.4.2, 13.4.3 and
13.4.4
Multiviewer Outputs
If the Multiviewer Crosspoint Module is fitted it receives signals from the input modules after
any processing has been carried out.
Input/Output Monitoring Outputs
If an Input/Output Monitoring Module is fitted each monitoring output can be independently
configured to display either an input or an output signal. Each monitoring output can also be
independently configured to display a signal before or after processing has been applied to it
(processing modules only).
Up to four monitor signals are passed to the BNC connectors on the 1287 Control rear panel
(see section 16.2).
Figure 16 Sirius 850 Signal Flow Diagram
*
Monitor Input Module (5930) only required if the
Multiviewer Crosspoint Module (5902) is not fitted.
Rea
r Mo
unted
Re
ar
M
oun
te
d
F
ront
Mou
n
ted
** The “before or after processing”
option is only available for
processing modules