Using RollCall
Use the RollCall application or the RollCall web applet to connect to the router. Double click
on the controller in the network tree and select the
Comms Setup
screen.
Available Settings:
•
Unit IP Address: set the IP address of the controller
•
Subnet Mask: set to match the network
•
Default Gateway Address: if unknown or not required enter 0.0.0.0
•
DCCP Port: if blank then the network port will be the default value which is 2007
14.4.8 Setting the Network Communication Speed of a Nucleus2 Controller
The Nucleus2 network communication speed is set using the Workbench Online Editor in the
IP address configuration section, see section 14.4.7 for details.
Note:
•
If RollCall does not connect to the router controller check that the controller is
enabled for RollCall, see section 14.4.9 for details.
Note:
•
The changes will not take effect until the controller has been restarted. Click on the
Restart Unit
button to restart the Nucleus2 router control module.
•
Having changed the controller IP address remember to use its new IP address to
connect to it.
•
If the controller is one of a pair in the router the other controller’s replication
address details must be changed to match the new IP address details set (see
section 14.4.6 for details).