Sirius 800 Series User Manual
2464/2463 Nucleus2 Router Control Module
Nucleus Router Control Modules 14.4
Iss 5 Rev 7
Page 266
© 2017 SAM
Sirius 850 Dual Frames: Frame 2 of 2
(Frame ID Switch set to 2 - see section 16.3.1)
Table 72 shows the Sirius 850 crosspoint address mapping for Frame 2 of 2:
14.4.6 Configuring Nucleus2 Controller Replication
When two Nucleus2 router controllers are fitted in a Sirius 800 router they work as a main and
redundant pair. The active controller in the pair sends the inactive controller data such as;
crosspoint status, module configuration and port configuration. This means if the active
controller fails the other controller in the pair has the latest information available to it at all
times.
To enable this function each controller must be configured with the details of the other. The
replication address can be configured by using Workbench or RollCall.
Using Workbench
Nucleus2 Router Control Module Navigate to:
ConfigurationItems | ReplicatedPeer
•
Name
= enter the name of the controller that will be the replicated peer as shown on
the Workbench configuration screen
•
IPAddress
= enter the IP address of the controller that will be the replicated peer as
shown on the Workbench configuration screen
•
IPPort
= if blank then the network port will be the default value which is 2007
•
ConnectionState
= True or False - this is a status and is read only
•
Active
= True or False - this is a status and is read only
Input/Output Range
Addresses
Video Inputs
1 to 1152
Source 0 to 1151
Main Video Outputs
(using 5928 expansion modules &
1365/1290 expansion output
rear panels)
577 to 1152
Destination 576 to 1151
*Multiviewer Outputs
(using two 1291 multiviewer
rear panels)
1 to 96
Destination 1292 to 1339
&
Destination 1364 to 1411
Destinations 1 to 576 are not used and do not respond to any control
*Multiviewer Outputs: 1292 to 1431 only if two 1292 multiviewer MV-Link rear panels are fitted
- (no longer supplied)
Monitoring Outputs
1 to 4
Destination 16370 to 16373
Audio Inputs
(Nucleus2 only)
1 to 18432
Source 0 to 18431
Audio Outputs
(Nucleus2 only)
1 to 18432
Destination 0 to 18431
Table 72
Sirius 850 Input and Output Port Mapping (Frame 2 of 2)
Note:
•
Changes will not take effect until the controller has been reset.