Sirius 800 Series User Manual
5902 Sirius 800 Multiviewer Crosspoint
Multiviewer & Input/Output Monitoring Modules 13.5
Iss 5 Rev 7
Page 238
© 2017 SAM
13.5 5902 Sirius 800 Multiviewer Crosspoint
The 5902 Sirius 800 series multiviewer crosspoint module is a 576x144 crosspoint, taking all
the input signals and routing them to a multiviewer output module.
The multiviewer output of the 5902 is connected to up to three 5931 (Sirius 850 up to two)
external multiviewer output modules, see section 13.6 for details.
13.5.1 Sirius 840/850 only
The 5902 Sirius 800 series multiviewer crosspoint module provides up to four signals for input
monitoring to the 5933 output monitor module (see section 13.8.2). The 5933 output monitor
module passes the signals onto the BNC monitor connectors on the control panel rear (see
section 16.2).
Figure 166 5902 Sirius 800 Series Multiviewer Crosspoint Module
Note:
•
There is no crosspoint redundancy protection.
•
Sirius 830
: Output Monitoring is not available on the Sirius 830 when it is equipped
with multiviewer outputs.
•
Sirius 840/850
: If Input pre-processing is monitored using the monitor outputs then
multiviewer outputs should not be routed from inputs 1, 3, 5 and 7 of any video
input module as they will display duplicates of the four monitoring outputs.
LEDs
Connectors to