8.3.4 Alternative Dual Power Shelf Connections
This connection method is suitable for systems with two power shelves and is often used
when a system is expanded from one power supply shelf to two power supply shelves.
Two separate mains supplies should be used to maintain redundancy in the event of one
supply failing.
Note:
An individual power supply shelf cannot be isolated when connected in this configuration. If
you need to be able to isolate an individual power supply shelf the mains supplies should
be connected as described in section 8.3.3.
Fig 24. Power and Alarm Connections
There is one spare 48 V DC connector on each power supply shelf. Do not remove the
covers of the unused connectors.
Note:
The three 48 V DC power connectors on each power supply shelf are common. Any two of
the three sockets on each power supply shelf can be used to power the router.
Functional Earth Stud
48 V DC Power Connectors
25-Way
D-Type Alarm
Connection
Functional
Earth
PSU Alarm
Connectors
Protective Earth
AC Power
Cables with
PowerCon
Connectors
Protective
Earth
Mains
Supply A
Mains
Supply B
Mains
Supply A
Mains
Supply B
Summary of Contents for Sirius 830
Page 2: ...Sirius 830 Installation Manual www s a m com Issue 2 Rev 2 Page 2 2016 SAM...
Page 6: ...Sirius 830 Installation Manual www s a m com About this Manual Issue 2 Rev 2 Page 6 2016 SAM...
Page 24: ...Sirius 830 Installation Manual www s a m com Installation Issue 2 Rev 2 Page 24 2016 SAM...
Page 28: ...Sirius 830 Installation Manual www s a m com Rear Connectors Issue 2 Rev 2 Page 28 2016 SAM...
Page 72: ...Sirius 830 Installation Manual www s a m com Workbench Issue 2 Rev 2 Page 72 2016 SAM...