![Salvis ProfiLine PLGGH Series Operating Instructions Manual Download Page 34](http://html1.mh-extra.com/html/salvis/profiline-plggh-series/profiline-plggh-series_operating-instructions-manual_804161034.webp)
en
34 / 44
8.
Technical specifications
For the description of the gas oven or gas hob, refer to the separate operating Instructions!
Technical specifications
Gas baking oven
Item No.
Installed in appliances:
PLGGH - PL880648
4-flame gas oven with gas baking oven
PLGGH - PL880645
6-flame gas oven with gas baking oven
PLGGF - PL881061
gas hob with gas baking oven
Category
Refer to page 35 Chapter 9.1.1
Type of gas appliance
A1
Overall nominal heat input
Gas baking oven 8 kW
Rating gas baking oven
8 kW
Gas connection diameter
R 3/4
Consumption at rated power
Natural gas G20
0,85 m
3
/h
Consumption at rated power
Natural gas G25 / G25.1
0,98 m
3
/h
Consumption at rated power
Liquid gas G30 / G31
0,63 kg/h
Internal dimensions, gas baking oven
575 x 665 x 280 mm
Appliance noise level
less than 70dB (A)
We reserve the right to make technical changes
9.
Switching to another type of gas
Observe the notes regarding safe operation, refer to page 26 Chapter 2.
DANGER! Risk of explosion!
.
Before assembly and conversion tasks, close the gas tap on the appliance and on
site!
.
Lock the on-site gas tap against unintentional opening!
.
Place a sign at the on-site gas tap to indicate that work is in progress on the gas
system!
● Only use original nozzles
when switching to another type of gas.
.
After switching to another type of gas and after maintenance tasks:
−
Check all parts carrying gas for tightness (leak spray).
−
Install identification of the type of gas and gas supply pressure on the gas oven.
.
Allocate and determine the nozzles and settings required, refer to the following chapter 9.1