![Salvis Evolino Pro Operation Manual Download Page 30](http://html1.mh-extra.com/html/salvis/evolino-pro/evolino-pro_operation-manual_3673220030.webp)
28
7.7.4 Manual
Cleaning
We recommend to set the Climatic Cursor to 60° C/100% humidity level.
Confirm setting with
OK.
Use arrow and proceed to the time field.
Use arrows or and set 10 minutes.
Press START/STOP.
Grids and fat filter may be left inside the oven.
As soon as the time has run down, there is a sound signal. Spray special
cleaner thoroughly into the cooking chamber and on to hang-in racks etc.
Do not spray cleaning agent in a hot oven cavity
.
Leave cleaner to work for 5 - 10 minutes.
Observe the manufacturer's instructions.
Press START/STOP.
As soon as the time has run down, there is a sound signal. The oven switches off.
If necessary repeat this procedure.
Rinse cooking chamber thoroughly with water, using the hand shower.
Remove drain-sieve and rinse with water. Switch off (ON/OFF) before rinsing
Use the shower only for rinsing the interior but not for outer surfaces.
In case cleaning agent remains in the cooking chamber, this may cause
corrosion problems.
Dry the device setting the temperature 130°C, humidity 0%, and time about 10 min.
and start with Start/Stop.
After cleaning open the door a small gap, so that the cooking chamber is well ventilated.
Do not damage thermostat sensor when cleaning!
7.7.5 Hints on operational safety
Only recommended original cleaning agents may be used
.
All safety devices inside the unit have been designed to the use of these products in order to
comply with the standard specifications of the drinking water supply.
The factory bears no liability for any damages caused by the use of any other cleaning
products (cleaner and rinse agent) than mentioned above.
Exchange of canisters and refilling of cleaner and rinse agent.
Observe the directions of the manufacturer and wear suitable protective clothing, gloves and glasses.
For safety reasons, the door must not be opened during an autoclean program.
Cleaner, rinse agent, hot water and steam may escape. If it is absolutely necessary to open
the door, the autoclean program must be stopped.
If the oven is not used for an extended period of time, rinse the whole Autoclean
system thoroughly with lukewarm water to avoid clogging caused by cleaner and
rinse-agent remainders.
Remove screwings from the canisters and clean the tube ends and the filter in warm water.
Start autoclean step
Flushing
and rinse the appliance until no more cleaner is remaining
inside the tubes and the cabinet.
Preparation for cleaning
Prior to starting a cleaning program make sure that there is sufficient cleaner and rinse agent in the
respective canisters.
Visual control.
No food products should be in the cooking chamber.
Exchange of canisters
In case there is not sufficient cleaner or rinse agent left, the canisters must be
exchanged or refilled. Please ensure that correct connections are made.
•
Select autoclean with the sensor key
Special Programme
, and confirm with
OK
.
•
Use the arrow keys and to select operation and start with
.
•
AUTOCLEAN is ready for use.