background image

SALVIS AG

        CH-4665 Oftringen         www.salvis.ch 

 

 

 

Salvis Combi-Steamer Evolino Pro 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Manual 

 

 

 

 

 

Summary of Contents for Evolino Pro

Page 1: ...SALVIS AG CH 4665 Oftringen www salvis ch Salvis Combi Steamer Evolino Pro Operation Manual...

Page 2: ......

Page 3: ...automatic operation 19 6 1 Select and start a program via menu group 19 6 2 Picto operation 19 7 Special Programs 20 7 1 Regenerating 20 7 2 LT Cooking Low temperature 21 7 3 Cook Hold 22 7 4 Delta T...

Page 4: ...ptronic Temperatures and humidity levels are displayed in the movable Climatic cursor Every movement of the Climatic Cursor generates a change of the cooking parameters temperature and humidity one af...

Page 5: ...or the unit Pay attention to connect correctly to hard and soft water 1 2 Operation Caution The outer surfaces become hot in operation The convection steamer shall only be operated by trained staff fo...

Page 6: ...d plate condensers 1 5 Hand shower The appliance is equipped with a hand shower Water runs only when the oven is switched on How to work the shower Pull it out Hold the hose with one hand and press th...

Page 7: ...n appears Touch master key to switch on the start up screen appears The red part of the screen represents dry heat the blue one moist heat The Climatic Cursor indicates the temperature in degrees in r...

Page 8: ...perature T 150 C and humidity H 50 Below in horizontal lines time and core temperature symbols are displayed 3 1 Manual input Use the direction arrows to select a cooking procedure by adjusting the de...

Page 9: ...ombi steamer LED START is lit If desired you can activate the preheating by pressing the key PreHeat see Sec 9 The Climatic Monitor indicates data of the advancing program Manual operation Manual oper...

Page 10: ...2 1st step Input 140 C 50 Core temperature 72 C 2nd step Input 170 C 10 Core temperature 78 C Remaining time Total time Step 1 2 Set final core temperature step 2 Actual core temp Manual Steam Change...

Page 11: ...turn to the start up screen and entered not stored data is lost 3 5 Display of the actual situation Steptronic Exampl A program consisting of several steps was entered the second step including core t...

Page 12: ...tings for a cooking step while running a cooking programme With the function key Save changes the changes will be active for the running programme Abnormal program end Pressing key while a program is...

Page 13: ...d if activated if activated the first step of a cooking program is defined as preheating step Start Time program start can be pre programmed 3 8 Delay start programming Manual input Go to Additional a...

Page 14: ...ity Proceed with the other settings as usual Symbol Display Cooking procedure Values Temperature Humidity Gratinating 230 0 Roasting 130 30 Steaming 99 100 Grilling 180 0 Regenerating 120 35 Stewing 9...

Page 15: ...imum length of programme names is 22 characters Press the sensor key Save to save the program The menu interface with the suggested menu groups opens Assign program to a menu group or save without a p...

Page 16: ...ther inputs see Sec 5 1 Change Program numbers Select program and confirm with OK Press sensor key Save Use direction arrows and proceed to input field Number confirm with OK The input field Number is...

Page 17: ...m with OK 2 Confirm program name with enter the cursor goes to Favourite Confirm with OK it is marked Program Info Use arrow and go to Program Info confirm with OK the input field appears and it is no...

Page 18: ...and confirm with OK Press sensor key Save See Sec 5 1 and write the new program name and or number confirm with Enter Press sensor key Save the program is copied or overwritten Thus the same program...

Page 19: ...rectional arrow 5 5 Select and start a Program from the Favourite List Favourites are marked with the smiley Press sensor key Favourites to bring up the list and use the arrows or to select a favourit...

Page 20: ...key Start time Use the arrows or to set the start time and start pressing key To stop this function press key The start screen displaying the program reappears By pressing key the program can be start...

Page 21: ...ay or display it by pressing OK and then start it with Start Stop 6 2 Picto operation If only one program belongs to a menu group the program opens directly if you select that menu group If you select...

Page 22: ...tructions in Sec 5 1 When such a program is saved the letter B appears automatically at the beginning of its name in order to identify it in the program list Additional functions regenerating Use arro...

Page 23: ...tion Preheat as described in Sec 9 It is possible to enter up to 12 different cooking steps in an LT program see Sec 3 4 Use arrow set time and or core temperature and start To save an LT program foll...

Page 24: ...equently for instance it is possible to start roasting at higher temperatures Select function Preheat as described in Sec 9 It is possible to enter up to 5 different cooking steps in a Cook Hold progr...

Page 25: ...y at the beginning of its name in order to identify it in the program list In a T cooking process the cooking chamber temperature is adjusted to the increasing core temperature Example Input T 50 C co...

Page 26: ...h OK the display break time indicates 0 sec Set the rest time between 0 99 seconds with the arrow keys You can set rest time 0 too When baking step input the time must always be entered if not the fol...

Page 27: ...printing at least 40 characters per line Printer adjustment 9600 N 8 1 The port for the cable connection is on the right side of the control panel Plug No EXTERN 9pin Min D bushing Function RS 232 C...

Page 28: ...s day can be selected by scrolling with the arrows Confirm the program that is supposed to be printed with OK and touch sensor key Print to have it printed By pressing sensor key Print 7 the programs...

Page 29: ...enever the cooking chamber temperature is too high the cool down function starts automatically and cools the appliance down to 80 C The display indicates Unit cooling down Once the temperature is reac...

Page 30: ...hese products in order to comply with the standard specifications of the drinking water supply The factory bears no liability for any damages caused by the use of any other cleaning products cleaner a...

Page 31: ...started program is displayed If you started cooking procedure with KT temperature originally that procedure s core time and the remaining times of the other started program are displayed Display 1 Di...

Page 32: ...ere is a sound signal and the info line indicates Preheat Cool End The sound signal is repeated over and again until the door is opened The nominal temperature is maintained for 1 hour max Charge the...

Page 33: ...put 10 2 Setup 10 2 1 Time Date The correct date and time is set when the combi steamer is delivered However it may be necessary to change date and time Touch sensor key Special program Special and co...

Page 34: ...displayed in different languages Use arrows or and confirm whatever language you like with OK it is then marked 10 2 4 Unit parameters Use arrows and select Unit parameters Activate deactivate or cha...

Page 35: ...for soft water Check the water pressure switch Autoclean will pause until pressure is high enough Reset Autonomous when repaired Not enough water Is the appliance connected to water Check if water tap...

Page 36: ...or interruption Meat probe operation is possible Reset Autonomous when repaired 117 Water vapour elimination sensor no signal Warning Remedy sensor interruption Operation with a defective sensor is po...

Page 37: ...er follow the installation instructions Wrong cleaning agent Use recommended cleaner agents Remains of cleaning agent in the cooking chamber Wash the interior thoroughly and regularly use hand shower...

Page 38: ...leaning Clean only with a soft cloth Never use scouring agents Cleaning of outer surfaces Use fat grease dissolving cleaning agents or special stainless steel cleaners Cleaning of the grease fat filte...

Page 39: ...m Port on the PC It is possible to test the communication in the set up dialog for device address and port check communication Of course there are further individual possibilities for connection and c...

Page 40: ...SALVIS AG Nordstrasse 15 CH 4665 Oftringen Phone 41 62 788 1818 Fax 41 62 788 1895 www salvis ch info salvis ch...

Reviews: