ENGLISH
10
Following
coefficients
were
applied
to
basic
values
:
Pump
assembled
on
cast
iron
base:
Forces
:
0,4
x
F
base
Moments
:
0,4
x
F
base
Pump
assembled
on
grouted
cast
iron
base
frame
:
Forces
:
F
x
[1,5
–
(12,5/Flange
DN)]
Moments
:
M
x
(1
+
Flange
DN/250)
Coefficient
due
to
flange
rating
:
C
=
1,45
on
forces
and
moments
Temperature
correction
for
temperature
>
110°C
:
C
=
E
tm
/
E
20b
With
E
20b
:
material
modulus
of
elasticity
at
20°C
and
E
tm
at
calculation
temperature.
Assembly
on
cast
iron
base
frame
:
Discharge
z
axis
:
DN
flan
ge
F
y
(N)
F
z
(N)
F
x
(N)
F
(N)
M
y
(N.m)
M
z
(N.m)
M
x
(N.m)
M
(N.m)
32
490
610
520
940
440
490
640
920
40
580
730
640
1130
520
610
750
1100
50
780
960
870
1510
580
670
810
1200
65
990
1220
1070
1900
640
700
870
1280
80
1190
1450
1310
2280
670
750
930
1370
100
1570
1940
1740
3040
730
840
1020
1500
125
1860
2290
2060
3600
870
1100
1220
1860
Suction
x
axis
:
DN
flan
ge
F
y
(N)
F
z
(N)
F
x
(N)
F
(N)
M
y
(N.m)
M
z
(N.m)
M
x
(N.m)
M
N.m)
50
870
780
960
1510
580
670
810
1200
65
1070
990
1220
1900
640
700
870
1280
80
1310
1190
1450
2280
670
750
930
1370
100
1740
1570
1940
3040
730
840
1020
1500
125
2060
1860
2290
3600
870
1100
1220
1860
150
2610
2350
2900
4550
1020
1190
1450
2130
Assembly
on
grouted
cast
iron
base
frame
:
Discharge
z
axis
:
DN
flan
ge
F
y
(N)
F
z
(N)
F
x
(N)
F
(N)
M
y
(N.m)
M
z
(N.m)
M
x
(N.m)
M
(N.m)
32
550
680
580
1040
490
560
720
1030
40
690
860
760
1340
610
710
870
1280
50
980
1200
1090
1890
700
800
970
1440
65
1290
1590
1400
2480
800
880
1100
1620
80
1600
1950
1750
3070
880
1000
1220
1810
100
2150
2670
2390
4180
1020
1180
1420
2110
125
2600
3210
2880
5030
1310
1650
1830
2790
Suction
x
axis
:
DN
flan
ge
F
y
(N)
F
z
(N)
F
x
(N)
F
(N)
M
y
(N.m)
M
z
(N.m)
M
x
(N.m)
M
N.m)
50
1090
980
1200
1890
700
800
970
1440
65
1400
1290
1590
2480
800
880
1100
1620
80
1750
1600
1950
3070
880
1000
1220
1810
100
2390
2150
2670
4180
1020
1180
1420
2110
125
2880
2600
3210
5030
1310
1650
1830
2790
150
3700
3330
4110
6450
1620
1900
2320
3410
5.2.7
SCOPE
OF
DELIVERY
Pump
can
be
delivered
as
a
complete
pump
set
including
electrical
motor,
flexible
coupling,
coupling
guard
and
baseplate.
It
can
be
also
delivered
without
one
of
those
parts.
A
CE
integration
certificate
is
then
supplied.
This
instructions
and
operating
manual
is
part
of
the
pump
supply
and
should
be
delivered
attached
to
the
pump.
If
not,
ask
SALMSON
Customer
department
to
get
it.
ATEX
pumps
may
be
delivered
with
specific
instrumentation.
Refer
to
pump
technical
datasheet
or
to
acknowledgment
of
order
to
know
exhaustive
scope
of
supply.
6
DESCRIPTION
AND
WORKING
PRINCIPLE
6.1
PRODUCT
INFORMATION
NFCH
pump
is
a
single
stage
PN16
volute
casing
pump
designed
for
horizontal
installation.
Dimensions
meet
EN733
requirements.
The
back
pull
‐
out
design
of
the
bearing
assembly
permits
dismantling
of
the
impeller
while
suction
and
discharge
lines
are
fastened
to
casing
flanges.
If
a
coupling
spacer
is
used
the
motor
won’t
have
to
be
moved
rearward
during
maintenance
operation.
This
pump
is
designed
to
handle
thermal
oils
up
to
350°C.
A
carbon
‐
antimony
bearing
located
behind
the
impeller
reduces
the
overhang.
Mechanical
seal
is
located
close
to
the
ball
bearing
assembly.
The
length
of
the
mechanical
seal
housing
and
its
inner
diameter
adjusted
to
pump
shaft
diameter
added
to
external
cooling
fins
reduce
drastically
fluid
temperature
in
mechanical
seal
chamber.
Thanks
to
this
specific
design
a
standard
sealing
without
external
cooling
is
used.
The
mechanical
seal
housing
design
added
to
a
vent
valve
makes
pump
venting
easier
and
reduces
the
risk
of
dry
running.
6.2
FUNCTION
NFCH
pump
is
a
centrifugal
pump
with
axial
fluid
inlet
and
radial
outlet.
Depending
on
required
discharge
pressure
the
pump
speed
can
be
1450
or
2900
RPM.
An
impeller
turns
inside
the
pump
casing
(direction
of
rotation
is
clockwise
seen
from
drive
end).
The
rotation
movement
is
transmitted
to
the
fluid
that
is
driven
to
the
vanes
and
then
pumped
to
the
discharge
flange
where
it
leaves
the
pump.
In
the
flow
passage
of
the
pump
casing
the
kinetic
energy
of
the
fluid
is
converted
into
pressure
energy.
NFCH
pumps
are
not
self
‐
priming
pumps.
Suction
line
and
pump
casing
should
be
completely
filled
with
liquid
before
pump
start.
When
necessary
or
when
a
maximum
pumping
efficiency
is
required
several
possibilities
are
offered
to
adapt
capacity/pressure.
Modification
of
the
system
hydraulic
characteristics
:
A
regulating
valve
is
added
at
the
discharge
side
of
the
pump.
The
hydraulic
loss
can
be
adjusted
and
so
the
pump
duty
point.
Modification
of
pump
characteristics
:
Use
of
a
frequency
inverter
gives
the
possibility
to
adjust
pump
speed.
The
pump
hydraulic
curve
is
modified
to
reach
required
duty
point
but
impeller
diameter
is
unchanged.
Summary of Contents for NFCH series
Page 2: ...NFCH INSTALLATION ET MISE EN SERVICE FRAN AIS N M S n 4095251 Ed 3 10 13...
Page 23: ...FRAN AIS 23 13 DECLARATION CE...
Page 24: ...NFCH INSTALLATION AND OPERATING INSTRUCTIONS ENGLISH N M S n 4095251 Ed 3 10 13...
Page 25: ...2...