PDS51 Series
- 27 -
Chapter 5 Parameters List
○
:
Indicates that the set value of this parameter can be changed when the controller is in
both stop and running state.
●
:
Indicates that the set value of this parameter cannot be changed when the controller is
running.
◎
:
Indicates that the value of this parameter is the measured record value or the
manufacturer's parameter, and cannot be changed.
Parameter
Name
Setting Range
Default
Value
Remarks
Fea-
ture
Communi
-cation
Address
F0 Team
:
Basic Parameters
F0.00
Motor Control
Mode
0
:
SVC
1
:
V/F
1
●
0x000
F0.01
Start/Stop
Source Option
0
:
Start/Stop Button
1
:
Terminal
2
:
RS485 Communication
0
●
0x001
F0.02
Speed/Tor-que
Control Mode
0
:
Speed Control
1
:
Torque Control
0
○
0x002
F0.03
Main Frequency
Source
0
:
Keypad,not retained after
power-off
1
:
Keypad,retained after
power-off
2
:
AI1
3
~
6
:
Reserved
7
:
Terminal UP/DOWN
8
:
MPPT
9
:
RS 485 Communication
10
:
Multi-Drive
Communication
8
●
0x003
F0.04
Auxiliary
Frequency
Source
0
:
Keypad,not retained after
power-off
1
:
Keypad,retained after
power-off
2
:
AI1
3
~
6
:
Reserved
1
●
0x004