PDS51 Series
- 32 -
Parameter
Name
Setting Range
Default
Value
Remarks
Fea-
ture
Communi
-cation
Address
connected at the
same time, real-time
power
complementation
ensures maximum
power output;
FD.02
System Mode
0
:
Single Drive Mode
1
:
Multi Drive Mode
0
●
0xD01
FD.03
Host and
Auxiliary
Setting in Multi
Drive Sytem
0
:
Host
1
:
1st Auxiliary
2
:
2nd Auxiliary
0
●
0xD02
FD.04
Screen Off
Delay
0min
~
1000min
30min
0 for never off
○
0xD03
FD.05
MPPT Voltage
Source
0
:
Keypad Setting
1
:
Automatic MPPT Setting
1
●
0xD04
FD.06
MPPT Voltage
Set Value
FD.14
~
FD.15
530.0V
○
0xD05
FD.07
Weak Light
Detection Time
0.0s
~
1000.0s
100.0s
○
0xD06
FD.08
Weak Light
Restart Time
0.0s
~
3600.0s
300.0s
○
0xD07
FD.09
MPPT Startup
Voltage Level
70.0%
~
100.0%
85.00%
○
0xD08
FD.10
MPPT Voc
250.0V
~
800.0V
750.0V
○
0xD09
FD.11
Auto Startup
Option
0
:
Invalid
1
:
Valid
1
○
0xD0A
FD.12
Auto Startup
Delay
0.0s
~
100.0s
15.0s
○
0xD0B
FD.13
MPPT Initial
Value
Adjustment
Range
0.0V
~
50.0V
30.0V
○
0xD0C
FD.14
Software Dry
Run Detection
Delay
0.0s
~
3600.0s
20.0s
○
0xD0D