PDS51 Series
- 5 -
■
Running
◎
The controller can be powered on after the wiring is completed and the cover is
installed. It is strictly forbidden to remove the cover when the power is on, otherwise it may
cause electric shock.
◎
The water pump must be installed before testing the steering of the water pump. The
water pump should not be allowed to do dry run for a long time. In order to test the steering
of the water pump, the maximum running time of dry running should not exceed 15s.
◎
If the rotation of the water pump is reversed, any two of the three cbales of the
controller output side can be changed.
◎
When the water pump stops due to weak sunlight or sudden shadow, it will restart
after 300s.
◎
If there is a water level probe installed in the well, the pump will stop running when
it is lower than the water shortage level.
■
Maintenance and Inspection
◎
Please designate qualified electrical engineers for maintenance, inspection or
replacement of parts.
◎
Wait at least 10 minutes after the power is turned off or after confirming that there
is no residual voltage before maintenance and inspection, otherwise it may cause personal
injury.
■
Others
◎
If the controller is damaged due to failure to follow the above instructions, the
warranty service will not be available.