PDS51 Series
- 29 -
Parameter
Name
Setting Range
Default
Value
Remarks
Fea-
ture
Communi
-cation
Address
settings,including F2 team
F2 Team
:
Motor Parameters
F2.00
Type of Motor
0
:
Ordinary 3 Phase
Asynchronous Motor
(
AM
)
1
:
3 Phase Permanent Magnet
Synchronous Motor
(
PMSM
)
2
:
Single Phase Motor
0
●
0x200
F2.01
Motor Rated
Power
0.4
~
11kW
Due to
Controller
Model
F2.00~F2.06 must be
set according to
motor nameplate
●
0x201
F2.02
Motor Rated
Voltage
1
~
480V
●
0x202
F2.03
Motor Rated
Current
0.1
~
50.0A
●
0x203
F2.04
Motor Rated
Frequency
0.01
~
F0.10
●
0x204
F2.05
Motor Rated
Speed
1
~
65000rpm
●
0x205
F2.06
Quantity of
Poles
2
~
48
4
●
0x206
F2.07
Motor
Non-Load
Current
0.1
~
50.0A
Due to
Controller
Model
●
0x207
F2.08
Motor Stator
Resistance
0.001
~
65.000
●
0x208
F2.09
Motor rotor
resistance
0.001
~
65.000
●
0x209
F2.10
Motor Leakage
Inductance
0.1
~
6500.0mH
●
0x20A
F2.11
Motor Mutual
Inductance
0.1
~
6500.0mH
●
0x20B
F2.12
Motor Tuning
Option
0
:
No Option
1
:
Full-Tuning
2
:
Quiet-Tuning
0
Option 1 for the
motors which can be
totally removed from
its load
Option 2 for the
●
0x20C