Proc Sheet 2 01
myZ-5
5HPRYHDQG3ODFH
7KHYLEUDWLQJGHYLFH
1/1
This operation must be done after license SAGEM COMMUNICATION
7RROV
- Phillips screwdriver
- Soldering iron
- Plait to be unsolder
-
Flat screwdriver
-
Plectrum
-
Gloves
3UHOLPLQDU\RSHUDWLRQ
1. Remove the battery (
Proc sheet 0 01
).
2. Remove the lower casing of mobile (
Proc sheet 1 01
).
3. Remove the equipped electronic board (
Proc Sheet 1 18
).
5HPRYDOSURFHGXUH
1. Remove the vibrating device from its housing first with a plectrum.
1. Unsolder the vibrating device on the equipped electronic board and take care of the wiring sense (2).
3ODFHPHQWSURFHGXUH
1. Flux the place of the vibrating device and solder it on the equipped electronic board, respecting the
wiring sense.
1. Position the vibrating device in its housing.
)XUWKHURSHUDWLRQV
1. Place the equipped electronic board (
Proc Sheet 1 18
).
2. Place the lower casing of mobile (
Proc sheet 1 01
).
3. Place the battery (
Proc sheet 0 01
).
Vibrating
device
Risk of the procedure:
•
Damage the equipped electronic board.
•
Oxide the equipped electronic board.
•
Reverse the vibrating device wiring.
•
Damage the vibrating device housing.
Procedure
Symptom
Test
REF MTB DTS 9- Indice B - December 09 2005
Page 5-31