Proc Sheet 1 26
myZ-5
5HPRYHDQG3ODFH
7KHORZHUFDVLQJRIWKHWKH)/$3
1/2
7RROV
- Phillips screwdriver.
-
Plectrum
-
Gloves
-
Tweezers
3UHOLPLQDU\RSHUDWLRQ
1. Remove the battery (
Proc sheet 0 01
).
2. Remove the lower casing of mobile (
Proc sheet 1 01
).
3. Remove the equipped electronic board (
Proc Sheet 1 18
).
4. Remove the keypad of lower casing of mobile (
Proc Sheet 1 04
).
5. Remove the upper casing of mobile (
Proc Sheet 1 13
).
5HPRYDOSURFHGXUH
1. Remove the two screw caches with the tweezers (1).
2. Remove the four fixing screws from the lower casing of the upper slide (2).
3. Dismantle the lower casing of the upper slide with the plectrum (3).
4. Lift delicately the lower casing taking care of FPC (4).
3ODFHPHQWSURFHGXUH
1. Place the new lower casing beginning to introduce delicately the FPC (4).
2. Assemble the lower casing (5).
3. Screw to an adapted torques the four fixing screw (1).
4. Place new screw caches (6).
)XUWKHURSHUDWLRQV
1. Place the upper casing of the mobile (
Proc Sheet 1 13
).
2. Place the keypad of the lower casing of mobile (
Proc Sheet 1 04
).
3. Place the equipped electronic board (
Proc Sheet 1 18
).
4. Place the lower casing of mobile (
Proc sheet 1 01
).
5. Place the battery (
Proc sheet 0 01
).
Risk of the procedure:
•
Damage the casing.
•
Break clips of casing.
•
Damage the FPC.
Procedure
Symptom
Test
REF MTB DTS 9- Indice B - December 09 2005
Page 5-21