MorphoWave
TM
OEM
– Installation guide
Section 3 : Installation Procedure
2015_2000009096 V4
May 2017
This document and the information therein are the property of Morpho.
They must not be copied or communicated to a third party without the prior written authorization of Morpho
41
MorphoAccess Sigma Wave Tamper Switch
Figure 17: MorphoAccess Sigma Wave Tamper switch wiring
A
3
Switch 1
Tamper switch contact
4
Switch 2
Strip on tamper switch
Operating principle for the switch
Product installed on the wall plate: switch enabled (contact closed).
Product opened (rear connectors accessible): switch disabled (contact open).
Nominal characteristics of switch block
100 mA at 30 VDC max (Resistive load) according to the safety extra low voltage
standard.
This MorphoWave
TM
OEM terminal is part of security system; it is
customer’s responsibility to connect the tamper switch (contact) to
physical access controller, in order to prevent the access to the connector
blocks.
Integrator Tamper Switch
Figure 18: Integrator Tamper switch wiring
C
3
Switch 1
Integrator
6
Switch 2
tamper switch
1
6
1
6
1
6
1
6
A
B
C
D
1
6
1
6
1
6
1
6
A
B
C
D