Instruction Manual 195 SG/SG-D/SG-FW
3/8
EN V. 2.0 --- 03.2019
so happen if the machine is run without any fog fluid (dry-run).
After cooling down (about 1 hour), the pump will automatically come back.
REMOTE CONTROL
All
SAFEX
®
-fog machines
can be operated by different
REMOTE CONTROL SYSTEMS
, in various and
most modern ways: (See leaflet
SAFEX
®
-FERNSTEUERUNGEN
).
SIMPLE-REMOTE CONTROL:
SIMPLEX-REMOTE CONTROL - ROBUST-REMOTE CONTROL
Simple cable-remote control with switch for FOG ON/OUT
Connect cable of the REMOTE CONTROL with
REMOTE CONTROL PLUG
and start fog by means of the
remote control switch.
Of course, the fog switch on the machine must be turned off and the fog output throttle opened,
when using all remote control systems.
SPECIAL SYSTEMS:
SAFEX
®
-FOG-CONTROLER
with
TIMER
and
ELECTRONIC FOG OUTPUT REGULATION
SAFEX
®
-RADIO-CONTROL-RADIO-REMOTE-CONTROL,
industrial quality
(Further interesting SYSTEMS as
the DMX-MODEM-U16 for
LOW-VOLTAGE REMOTE CONTROLS
for
COMPUTER
-connection or
DIMMER UNITS
etc. are available).
All remote control systems can be extended up to several hundreds of meters by means of special
remote control lines/-extensions. Proper laying is important.
SAFEX®-FOG-CONTROLER
The
SAFEX
®
-FOG-CONTROLER
allows to control continuously the fog output (even from a distance), like
this is possible with the FOG OUTPUT THROTTLE on the machine.
At the same time, it contains the control lamps MAINS and READY, so that also the remote control shows
the state of readiness of the fog machine.
SHORT INSTRUCTION:
1. Connect fog machine as usual and warm it up.
2. Connect special plug of the
SAFEX
®
-FOG-CONTROLER
with remote-control exit of the fog machine.
3. The switch „FOG“ on the machine must be in the „OUT-position“, the FOG OUTPUT THROTTLE must
be opened.
4. With the
SAFEX
®
-FOG-CONTROLER
fog can be produced with full power (100 %) or in controlled
quantity (1 - 10), by means of a flip-switch.
(For detailed information see instruction manual
SAFEX
®
-FOG-CONTROLER
)
MAINTENANCE
1. Empty the tank of the machine from time to time and rinse it with tap water to remove dirt, if necessary.
2. Fog output control valve will be self-cleaned by totally opening and closing the valve.
3. If necessary, remove dirt in the area of the fog outlet with a moistened cloth while machine is cold.
4. In case of dirt accumulation, rinse the siphon hose with filter with tap water contrary to the direction of
the fluid flow.
5. If the machine is used permanently, it should be sent in for a check-up every 2 years.