Instruction Manual 195 SG/SG-D/SG-FW
1/8
Attachment 1
- EN V.2.0 -03.2019
FOG GENERATOR 195 SG/SG-D/SG-FW
English Instruction Manual
Translation of Most Important Chapters of the German Instruction Manual.
(For illustrations see please the German instruction)
This instruction manual is divided into 5 parts:
A) SHORT INSTRUCTION
B) DESCRIPTION OF DIFFERENT FUNCTIONS
C) SAFETY PRECAUTIONS
D) TIPS FOR USE
E) TECHNICAL DATA
In order to be able to profit of all possibilities of the SAFEX
®
-FOG-SYSTEM, we recommend studying carefully the
total instruction.
A SHORT INSTRUCTION
(Kurzanleitung)
1.) Check machine physically for proper constitution. If desired, put hose adaptor on fog outlet protection
tube and fix it with screw when machine is cold.
2a.)
USE WITH INTERNAL TANK
Fill tank with
SAFEX
®
-INSIDE-NEBELFLUID
(max. 1,5 ltr.). Siphon hose in TANK must touch the bot-
tom with its FILTER and must be totally covered by fluid.
(
Important
: Use only clean and
original SAFEX
®
-INSIDE-NEBELFLUID
)
2b.)
USE WITH EXTERNAL TANK
See detailed tips in part „B“ - Internal/External tank
3.) Connect machine by original mains power cord to mains (see correct voltage on machine label). Now
turn on
mains
switch. Indicators for
MAINS, HEATING
and
COLD
must light now. (The switch
FOG
must not light, otherwise turn off immediately).
4.) Let machine warm up about 9 minutes, until the green indicator light
READY
turns on and indicator light
HEATING
turns off for the first time. The fog generator is now ready for use, as long as the green indi-
cator light remains on.
5.) Start fogging by turning on the
FOG
-switch
and
opening the
fog output throttle
.
IMPORTANT: Stop fogging only with FOG-switch, not by the fog output throttle.
Use fog-output throttle only for regulation of fog quantity.
NOTE: If the machine is newly filled or an external siphon hose is used, it will take a few seconds un-
til the fluid ways are filled. Within a short time, you can hear a different pump noise caused by
the air in the lines. This also happens in case of a deficiency of liquid.
B DESCRIPTION OF DIV. FUNCTION
HEATING
The temperature is regulated automatically, controlled by 3 independent control units. Heating stages are in-
Fig.
Page 4 + 5
Fig.
Page 7 + 8