12
8
7
6
5
4
3
2
1
RJ12
SL6+ v.3.30 EN
Installation
Wiring diagram
voice station
screw terminals
*Input A is configured with either:
• SafeLine Pro N/O (default) or N/C.
• Parameter *89*, please refer to the corresponding
code in the ”Parameter List”.
Connecting the
telephone line
Connect the telephone line parallell in universal terminals or the
RJ-plug, see picture above. It’s possible to connect up to nine
SL6+ main units to the same telephone line.
In order to access the unit remotely, it needs to be assigned a unit
number. Please refer to parameter *82* in the “Parameter List” for
more information.
Phone line is connected via RJ12 or terminal A through the
following:
1
2
3
4
5
6
Input
Not in use
Output
Output
Not in use
Input
7. Bus GND
8. Bus 12 VDC
6. Not in use
5. Input A*, alarm button
4. Output B, green pictogram
3. Output A, yellow pictogram
1. Bus A
2. Bus B
A common mode choke must be
used (2,2mH) for telephone line.