26
SL6+ v.3.30 EN
Configuration
TEST ALARM &
BATTERY ALARM
CODE DATA
COMMENTS
LMS phone number
*16*
- - - - - - - - - #
LMS (Lift Monitoring System) phone number
to alarm receiver or SLCC.
Test alarm
*17*
- - - - - - - - - #
Phone number to send testalarm to alarm
receiver or SLCC.
Call back test alarm
*19*
- - - - - - - - - #
Triggers a test alarm event to a user selected
phone number.
The call is made after the configuration is
terminated.
Days between tests
*27*
- - #
Number of days between test alarms, 00-99
days.
Always two digits.
Max 3 days according to EN 81-28.
00 = No test alarms
Test alarm protocol
*31*
- #
0 = P100
3 = CPC
4 = Caller ID
ALARM TYPE
CODE DATA
COMMENTS
Alarm type 1st number
*41*
- - #
Only when using CPC as alarm protocol
Normally 10 or 27, check with your alarm
company!
Alarm type 2nd number
*42*
- - #
Alarm type 3rd number
*43*
- - #
Alarm type 4th number
*44*
- - #
Alarm type LMS
*45*
- - #
LMS (Lift Monitoring System)
(Battery alarm)
Normally 17
Alarm type Test alarm
*46*
- - #
Normally 26