10
PSTN (RJ12)
PSTN
PSTN
VOICE STATIONS
VOICE STATIONS
VOICE STATIONS
VOICE STATIONS
COM. 1
N/C 1
N/O 1
N/O 2
N/C 2
COM. 2
230 VAC L
230 VAC N
A
B
C
D
E
F
SL6+ v.3.30 EN
Installation
Wiring diagram
SL6+ main unit
* Input 1 and 2 are configurable N/O or N/C inputs with SafeLine Pro
or CONNECT. For configuration details, se tabel to the left.
** Maximum 200 mA on the emergency bell output.
*** Maximum 500 mA on the emergency light output.
Phone line, RJ12
Relay 1 Common
Relay 1 N/C
Relay 1 N/O
Phone line
Phone line
Bus 12 VDC
Bus GND
Bus A
Bus B
B12 VDC
Battery 0 VDC
+12 VDC
Input 2*
(configurable)
Input 1*
(configurable)
Emerg. bell +**
Emerg. bell –**
Emerg. light +***
230 VAC L
230 VAC N
Emerg. light –***
Relay 2 Common
Relay 2 N/C
Relay 2 N/O
Connect the SL6 through a 63 mA fuse to terminal F, with a cable of
at least 1,5 mm².
Supply voltage for the SL6
must go through an all-pole
main switch in accordance with
EN81-20.
Connect the protective earth connection to the enclosure, with a
cable of at least 1,5mm².
Input 1 and 2 options
NONE
LMS/SMS
FILTER
CLEAR/MAINTENANCE
FIRE MODE
(default input 2)
ALARM BUTTON
(default input 1)