25
SL6+ v.3.30 EN
Configuration
(For more information, please refer to parameter *17*
in the ”Parameter list”)
Parameter list
CONFIGURATION DATA
CODE DATA
COMMENTS
Enter configuration mode
00
Enter password
* - - - - #
Default = 0000
Exit configuration mode
*00*#
ALARM CODES
CODE DATA
COMMENTS
P100 ID code
*01*
- - - - - - - - #
P100 is always 8 digits
CPC ID code
*02*
- - - - - - #
CPC 6-8 digits
Q23 ID code
*03*
- - - - - - - - - - - - #
Q23 is always 12 digits
TELEPHONE NUMBERS
CODE DATA
COMMENTS
1st Phone number
*11*
- - - - - - - - - #
Phone number to alarm receiver: 1-20 digits.
If calling through a switchboard, delay time
can be set by adding asterisks (*) between
leading number of the switchboard and
telephone number for the alarm call receiver.
Each asterisk (*) is equal to one second delay.
Example #1
: *11*0**1234567#
Example #2:
*11*# deletes the phone no.
2nd Phone number
*12*
- - - - - - - - - #
3rd Phone number
*13*
- - - - - - - - - #
4th Phone number
*14*
- - - - - - - - - #
CALL TYPE
CODE DATA
COMMENTS
Call type 1st number
*21*
- #
Change the call type of the stored telephone
numbers:
0 = P100
1 = VOICE (default)
2 = Q23
3 = CPC
Change this only if your alarm operator uses
any of the mentioned protocols.
Call type 2nd number
*22*
- #
Call type 3rd number
*23*
- #
Call type 4th number
*24*
- #
Call type LMS number
*30*
- #
LMS (Lift Monitoring System) call type
0 = P100
3 = CPC (Only battery alarm)
5 = SMS