During normal operation frequency response curve is smooth and the only equalizer tap towers
are in the centre of equalizer taps graph, otherwise frequency response curve will appear jagged and
many equalizer taps will become visible. The latter case most probably will indicate to multipath
issue, which must be inspected with use of precise and accurate path profiling. An example of
multipath caused equalization is shown on the picture below. Taps mainly on the right side designate
a weaker reflected signal in comparison with the main signal.
5.2.6
Performance Management Commands
It is also possible to view performance log in command prompt.
The list of available commands is the following: