The final screen allows checking the selected settings and applying them. The optional settings
are as follows:
–
Clear cfg file before the new settings will take place
– resetting or keeping all the other
parameters, not mentioned here, after configuration execution
–
Set local machine time
– uses the time of your laptop
–
Write this configuration into cfg file
– configuration is automatically written in
configuration file
Figure 2.18.
STEP 4. Checking settings and executing configuration
To verify the settings, we can go to ‘Main status’ page (Status
Main status). If there are no ‘red
fields’ after completing configuration wizard on both ends of the link, everything is set correctly and
the link is up.
2.6
Command Prompt Interface
CFIP equipment can be monitored and configured by using command interface described in this
chapter.
This process is performed by connecting to Telnet terminal via Ethernet port; Telnet
management supports only one client.
Command line management interface offers wider configuration and monitoring functionality.
The available commands for Telnet management are found in detailed explanation of Web GUI
windows, as well as in tables of additional commands.
(!)
−
To end Telnet session press Ctrl+D. Opening the session again, the prompt will appear to enter
username and password.
−
Default username is
admin
and password -
changeme
(!)
Syntactic notes for command prompt commands
–
Commands are in
bold
font.
–
All arguments (variables) are in
italic
font.
The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide • Rev. 1.10 •
© SAF Tehnika JSC 2013