4.2.4
Upgrade Software
1.
Choose file
– allows choosing location of software upgrade file (e.g. cfipl153.elf.ezip)
stored on your hard disk. Software upgrade file must have *.elf.ezip extension.
4.2.5.
Service information
1.
Open full system information page / Download system information
– allows to
open/save full system information page. Links on the top of opened page (“Open
full system information page”) allow you to save full system information page and
alarm log in separate txt files on your hard disk drive;
2.
Open advanced ethernet information page / Download ethernet statistics
– allows
to open/save advanced Ethernet statistics. Link on the top of opened page (“Open
advanced ethernet information page”) allows you to save advanced Ethernet
statistics page in separate txt file on your hard disk drive;
3.
System returned -
in case of error or incorrectly entered parameter value, or other
problems in the whole page – the info message will be displayed here. Otherwise it
says “Ok”.
(!)
Note that Advanced Ethernet information page resets all counters and gathers Ethernet
information. Please wait until information is gathered and displayed.
Additional system commands in Telnet/serial interface
Command
Description
System status
Displays the name of the device and its uptime.
System inventory
[ show ]
Displays the CFIP Lumina product code, serial number and additional
information.
System aliases
[
list | all | basic | off |
add | remove | clear ]
list
– shows the alias list and whether the aliases are going to be
used. The user can choose whether to see all the aliases (adding
the argument “all”), built-in aliases (“built-in”), or optional aliases
(“optional”) , or user aliases (“user”);
all
– all the aliases will be used;
basic
– only basic (built-in, hidden and user) aliases will be used;
off
– no aliases will be used;
add
– if two arguments are given, creates an alias of the second
argument, named as the first argument. If one argument given,
alias command tries and loads the aliases from a file specified by
the argument;
remove
– removes the alias specified by the argument;
clear
– removes all the user aliases.
System commands
[
show | help ]
show
– displays all available commands;
help
– displays available help messages for all commands.
System reset
[cold]
Restarts CPU of the management controller. Resets all management
counters.
The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide • Rev. 1.10 •