900 Convertible Top Troubleshooting Guide
Grinding, ticking when raising top
Tonneau motor not fully engaged?
Replace Tonneau motor assembly. Recheck cable adjustment. See pages
22-227 of Service Manual
and also Operational Problem
above for
additional illustration.
20. Top does not go up (rise) evenly one side rises quicker than the
other
Weak main motor?
Replace faulty motor and reprogram top. See page 222 of Service Manual
Cabriolet.
21. First bow slams header when raising top
a. Top stops misadjusted?
Adjust top stops. See page 130 of Service Manual
Cabriolet. Reprogram
top.
If problem persists, when calculating main motor high limit on Line A, subtract
4 units rather than 3.
b. Shim adjustment?
Remove shims (if present) to move top stack forward. Add shims to move
top stack rearward.
c. Loose screws
See Step E in Customer Satisfaction Campaign 428, PSI
bow header pins do not reach guide holes in header
a. Top stops misadjusted?
Adjust top stops. See page 130 of Service Manual
Cabriolet. Reprogram
top.
b. Shim adjustment?
Remove shims (if present) to move top stack forward. Add shims to move
top stack rearward.
15