2.4 Jumper
Description
Nbr
Function
X6: Serial
Interface
X9: Power
J6: DSP
Signals
J2:
Wetting Current Channel A (to N-Side)
J3:
Wetting Current Channel B (to C-Side)
X8:
Passthrough 2-Wire Remote Power
X10: Only Holder for Jumper, No Signals
X1:
Passthrough 4-Wire Remote Power
X11: Only Holder for Interconnect, No Signals
X12: Interconnection Remote Power to Local Power
X3: Interconnection
Remote Power to Local Power
2.4.1 Jumper settings for 2-Wire Repeater (Only PCB 1)
Nbr
Required Settings
X6: Open
X9: Open
J6:
Close 6 jumpers, interconnect DSP signals
J2:
Close for Wetting Current Channel A On
Open for Wetting Current Channel A Off
J3:
Close for Wetting Current Channel B On
Open for Wetting Current Channel B On
X8:
Close for Pass-through 2-Wire Remote Power
Open for not Pass-through 2-Wire Remote
Power
X10: Only Holder for Jumper, No Signals
X1: Open
X11: Open
X12: Open
X3: Open
2.4.2 Jumper settings for 4-Wire Repeater
Nbr
Required Settings
X6:
Interconnect PCB1 to PCB 2
X9:
Interconnect PCB1 to PCB 2
J6:
Interconnect PCB1 to PCB 2
J2:
Close for Wetting Current Channel A On (PCB1/2)
Open for Wetting Current Channel A Off (PCB1/2)
J3:
Close for Wetting Current Channel B On (PCB1/2)
Open for Wetting Current Channel B On (PCB1/2)
X8: Open
X10: Open
X1:
Interconnect Passthrough 4-Wire Remote Power
No Passthrough 4-Wire Remote Power
X11: Only Holder for Interconnect, No Signals
X12: Interconnect PCB1 to PCB 2
X3:
Interconnect PCB1 to PCB 2