8.3.3.2 RESETG826
Command
The RESETG826 command sets the G.826 error performance parameters back to zero.
RR_00_PM>RESETG826
G.826 error performance parameter reset
RR_00_PM>
8.3.4 Fault and maintenance management FMM
Fault and maintenance management activated
Enter <M> to return to MAIN, or <H> for HELP information
Type <H>and the monitor lists all available commands in the fault and maintenance sub-menu.
8.3.4.1 NM
Command
The NM command allows the user to switch on/off the signal quality of the DSL lines:
RR_00_FMM>NM
Noise margin trace on
xDSL NM: Mst-Side ChA: 10.9dB, ChB: 11.2dB Slv-Side ChA: 15.8dB, ChB: 15.4dB
Noise margin trace off
RR_00_FMM>