8.3.5.6 BASERATE
Command
This command sets the base rate for xDSL interface. This value must be between 3 and 32 and
defines the available 64 kbit/s channels. To optimize the bandwidth of your connection, you have to
set the base rate value to the maximum where you get a stable connection.
Parameters: 3
→
32
8.3.5.7 ADAPTIVE
Command
Set rate adaption on / off.
Parameters: on
off
8.3.5.8 DEFAULT
Command
The DEFAULT command sets a default configuration. Six default settings are available (three for
master, three for slave) in each of following modes: E1 only Normal or Dual Pair mode; Nx64 only