SA-4W-REPEATER
User Manual
S-Access GmbH
Tel: +41 44 700 31 11
Oberhausenstrasse 47
Page
16
of
26
Fax: +41 44 700 31 03
8907 Wettswil a/A
Email:
Switzerland
WEB:
www.s-access.ch
8.3.4.2 STATUS
Command
The STATUS command displays the actual system status:
----------------------------------------------------------------------
Local System Status: N-Side CH A CH B C-Side CH A CH B
----------------------------------------------------------------------
LOSD : 1 1 1 1
SEGA : 1 1 1 1
PS : 1 1 1 1
SEGD : 1 1 1 1
Tx power : 07.5 07.5 dBm 07.5 07.5 dBm
Rx gain : 13.4 13.7 dB 14.0 13.4 dB
Loop attn.: 00.0 00.0 dB 00.0 00.0 dB
NM : 26.2 27.0 dB 25.8 26.2 dB
Bitrate : 1024 1024 kBit/s 1024 1024 kBit/s
----------------------------------------------------------------------
RR_03_FMM>
Definitions:
LOSD:
(Loss of Signal) Indicates the loss of signal from the application
interface. Loss of Signal = 0, Normal = 1.
SEGA:
(Segment Anomaly) Indicates a CRC error on the incoming xDSL
frame. A segment anomaly indicates that a regenerator operating
on a segment has received corrupted data and therefore the
regenerated data is unreliable. CRC Error =0, Normal = 1.
PS:
(Power Status)
SEGD: (Segment
Defect)
Tx power:
Local transmit power in dBm
Rx gain:
Local receiver gain in dB
Loop attn.:
Estimate of the loop attenuation in dB of the actual connection
NM: Noise
margin
Bitrate:
Bitrate of the actual connection
8.3.4.3 ALARM
Command
The ALARM command displays the actual alarm status:
CO_01_FMM> ALARM
RR_03_FMM>
----------------------------------------------------------------------
Local Alarm Status: Mst-Side CH A CH B Slv-Side CH A CH B
----------------------------------------------------------------------
LOS/LFA-H: off off off off
SEGD : off off off off
BER-H : off off off off
LOOP2 : off
----------------------------------------------------------------------
RR_03_FMM>CO_01_FMM>
Options:
T
Turns alarm trace on / off