background image

 

RUSH MH 2 Wash user manual 

15 

 
Fixture overview 

 

LEDs 

The two LEDs on the front of the base give the following indications: 

DMX 

 On 

 Valid DMX input received 

SOUND 

 Flashing 

 Sound activation (music trig) 

 
Buttons 

The buttons below the display panel have the following functions: 

MENU 

  Activate the menu mode functions, or 

  Return to the previous level of the menu 

structure, or 

  Hold to exit the menus 

DOWN 

 Go down a menu branch 

UP 

 Go up a menu branch 

ENTER 

 Confirm the selected function 

 
Press and hold the MENU button to exit the menus (the fixture exits 
automatically after 60 seconds when there has been no user input). 

Connections 

The rear of the base has a blue Neutrik PowerCon socket for MAINS IN and a 
light-grey Neutrik PowerCon socket for MAINS OUT (thru) connections. There 
are also 3-pin and 5-pin XLR sockets for DMX data IN and OUT (thru).  

Fuse 

The T 6.3 A primary fuse F1 is located in a fuseholder next to the MAINS IN 
and OUT sockets. 

Summary of Contents for MH 2 Wash

Page 1: ...MH 2 Wash User Manual Professional Entertainment Technology...

Page 2: ...ability to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this document pertain...

Page 3: ...a link 16 Fixture setup 17 Using the control menus 17 DMX addressing 17 Show Mode stand alone operation 18 Sound activation in Show Mode 18 Dimming curves 19 Pan tilt inversion 19 Backlight 20 White b...

Page 4: ...Replacing the primary fuse 26 Service and repairs 26 DMX protocol 27 Control menus 30 Troubleshooting 32 Specifications 34...

Page 5: ...e that may concentrate the beam This lighting fixture is for professional use only and must be installed by a qualified technician It is not for household use It presents risks of severe injury or dea...

Page 6: ...used to supply the fixture with power must be located near the fixture and easily accessible so that the fixture can easily be disconnected from power Replace defective fuses with ones of the specifie...

Page 7: ...linked chain MAINS OUT throughput socket to MAINS IN input socket but do not link more than six 6 RUSH MH 2 fixtures in total at 100 120 V or twelve 12 RUSH MH 2 fixtures in total at 200 240 V The vo...

Page 8: ...ing on or near the fixture Protection from injury Fasten the fixture securely to a fixed surface or structure when in use The fixture is not portable when installed Ensure that any supporting structur...

Page 9: ...s shields or any optical component Do not lift or carry the fixture by its head Support the fixture by its base only In the event of an operating problem stop using the fixture immediately and disconn...

Page 10: ...ion on page 5 before installing operating or servicing the fixture 2 Unpack and ensure that there is no transportation damage before using the fixture Do not attempt to operate a damaged fixture 3 If...

Page 11: ...fixture securely Do not stand it on a surface or leave it where it can be moved or fall over If you install the fixture in a location where it may cause injury or damage if it falls secure it as direc...

Page 12: ...s so that the fixture is suspended securely 6 Secure the fixture with a safety cable as directed below 7 Check that the head will not collide with other fixtures or objects Securing with a safety cabl...

Page 13: ...ower Do not insert or remove live Neutrik PowerCon connectors to apply or cut power as this may cause arcing at the terminals that will damage the connectors Do not use an external dimming system to s...

Page 14: ...er by connecting fixtures to power in a linked daisy chain MAINS OUT throughput socket to MAINS IN input socket Using 14 AWG or 1 5 mm2 cables from Martin you can link Maximum six 6 RUSH MH 2 fixtures...

Page 15: ...Hold to exit the menus DOWN Go down a menu branch UP Go up a menu branch ENTER Confirm the selected function Press and hold the MENU button to exit the menus the fixture exits automatically after 60...

Page 16: ...ier is recommended for longer runs The pin out on all connectors is pin 1 shield pin 2 cold and pin 3 hot Pins 4 and 5 in the 5 pin XLR connectors are not used in the fixture but are available for pos...

Page 17: ...ler The fixture can be controlled using signals sent by a DMX controller on twelve channels Each DMX controlled fixture must have a DMX address set For example if a fixture has a DMX address of 10 the...

Page 18: ...ress MENU to exit without saving any changes Sound activation in Show Mode Show Mode can be combined with sound activation The fixture has a built in microphone that can be used to trigger scene chang...

Page 19: ...currently active will blink in the display 2 Use the DOWN and UP buttons to select Mode1 Mode 2 Mode 3 or Mode 4 3 Press ENTER to save your selection or press MENU to exit without saving any changes P...

Page 20: ...To adjust the fixture s white balance 1 Select WHITE BALANCE and press ENTER to confirm 2 Use the DOWN and UP buttons to select RED GREEN or BLUE 3 Once the color has been selected press ENTER 4 Use...

Page 21: ...ceived 3 Press ENTER to save your selection or press MENU to exit without saving any changes Manual test Fixture functions can be tested or controlled manually 1 Select MANUAL TEST and press ENTER 2 U...

Page 22: ...d press ENTER The display will blink 2 Use the DOWN and UP buttons to select YES 3 Press ENTER to restore the default settings or press MENU to exit without saving any changes Reset The fixture resets...

Page 23: ...le blackout during pan and tilt movement When enabled the fixture blacks out when the head moves and lights up again as soon as the head stands still Effects and dimming can be optimized for speed or...

Page 24: ...ent and enable or disable blackout during movement of the head Strobe effects The strobe effects provide instant open and blackout variable speed regular and random strobe Electronic dimming Overall i...

Page 25: ...the highest level of performance throughout the product s lifetime Please contact Martin for details Cleaning Excessive dust smoke fluid and particle buildup degrades performance causes overheating a...

Page 26: ...ir Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Replacing the primary fuse If...

Page 27: ...utter open Strobe 6 random closing pulse fast to slow Shutter open Strobe 7 burst pulse fast to slow Shutter open Strobe 8 random burst pulse fast to slow Shutter open Strobe 9 sine wave fast to slow...

Page 28: ...pink LEE 345 Fuchsia pink LEE 194 Surprise pink LEE 181 Congo Blue LEE 071 Tokyo Blue LEE 120 Deep Blue LEE 079 Just Blue LEE 132 Medium Blue LEE 200 Double CT Blue LEE 161 Slate Blue LEE 201 Full CT...

Page 29: ...34 235 239 240 244 245 249 250 255 Color wheel rotation effect Clockwise fast to slow Stop this will stop wherever the color is at the time Counter clockwise slow to fast Open Random color Fast Medium...

Page 30: ...ckout when no DMX No Fixture enters Show Mode when no DMX Sound State On Sound activation in Show Mode enabled Off Sound activation in Show Mode disabled Sound Sense 0 100 Microphone sensitivity for s...

Page 31: ...Dimmer 0 255 Manual control of dimmer Strobe 0 255 Manual control of strobe Auto test Automatic test of all functions Temp Temperature of onboard sensor Fixture Time Fixture operating hours counter Fi...

Page 32: ...sary replace the fixture fuse Fixture does not react to music beat Sound activation disabled Sound activation sensitivity too low for music source Ensure that fixture is not connected to a DMX signal...

Page 33: ...y to a high voltage installation Ensure that fixture s DMX address matches address set on DMX control device Check that fixture DMX LED is on and if not check all DMX cables and connections Ensure tha...

Page 34: ...dom regular variable speed Sound activation Adjustable microphone sensitivity Built in shows 4 pre programmed show modes Dimming Electronic 0 100 four dimmer curves Pan 540 Tilt 180 Pan tilt options I...

Page 35: ...asurements made at nominal voltage with all LEDs at full intensity Allow for a deviation of 10 Thermal Cooling Forced air Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta m...

Page 36: ...nt light grey P N 05342805 Installation hardware Half coupler clamp P N 91602005 G clamp P N 91602003 Quick trigger clamp P N 91602007 Safety cable safe working load 50 kg P N 91604003 Related Items R...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...I n n o v a t i o n Q u a l i t y P e r f o r m a n c e...

Reviews: