External Control
Runco LS-10d and LS-10HBd Installation/Operation Manual
83
PRE
L
IMINAR
Y
•
www
indicates the command code. This field is case insensitive; for example,
PWR
,
pwr
and
PwR
are all equivalent.
•
:x
is the destination parameter. This is an optional parameter that indicates which
memory the command is referencing. This parameter is reserved for future use.
•
z
is the new value (for Set, Increment or Decrement commands) or the current value
(for Get commands) for this parameter. It can have one of two formats:
•
Integer value:
Any positive or negative number; for example,
100
.
•
S
tring value:
Any string surrounded by double quotes; for example,
“This is a
string.”
•
[CR]
is the ASCII carriage return key (0x0D).
Command and Response
Examples
Here are some examples of serial commands and their responses:
Serial Command List
Table 6-1 lists all supported commands.
Command
Command Data
Re
s
pon
s
e
Power query when
unit is powered on
(PWR?) [CR]
(0;PWR=1) [CR]
Set power to 0 (off)
(PWR=0) [CR]
(0;PWR=0) [CR]
Increment bright-
ness from 24 to 25
(BRT+) [CR]
(0;BRT=25) [CR]
Invalid command
(ZZZ=0) [CR]
(1;ZZZ=0) [CR]
Invalid parameter
(received string,
expected integer)
(CON=”Some string”)
[CR]
(9;CON=”Some string”)
[CR]
Table 6-1.
S
erial Command
s
S
etting
Command
Code
Read/
Write
Inc/
Dec
Min
Value
Max
Value
S
tring?
Note
s
PCE Auto Color Enable
AAC
R/W
No
0
1
No
0 = Off; 1 = On
PCE Diagnostic Color
AAD
R/W
No
0
6
No
0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
PCE Blue x
ABX
R/W
Yes
-100
100
No
PCE Blue y
ABY
R/W
Yes
-100
100
No
PCE Green x
AGX
R/W
Yes
-100
100
No
PCE Green y
AGY
R/W
Yes
-100
100
No
Apply Image Alignment Values
AIA
R/W
No
0
1
No
0 = Off; 1 = On
Altitude
ALT
R/W
No
0
1
No
0 = Auto
1 = High