LFS-PM Series Live Focus System Operating Manual
8
Because the capacitor is a sensitive to temperature and humidity of the environment,
user should wait 3~5 minutes when power on to let the sensor and amplifier to reach a
stable temperature.
2.2.6 Auxiliary Gas Test
In the main menu, press “FUNCTION” to go to the “AUXI GAS” interface.
This function is used to test the auxiliary gas is good or not. Auxiliary gas testing
include of 3 channels auxiliary gas testing.
Testing steps
:
example for test the auxiliary gas with high pressure
,
press ”High
Pressure
”
,
then the auxiliary gas channel is turned on. Release the button, then turn of
the channel.
Notice: Before testing the auxiliary gas, make sure the control system is in the
standby status. Or the testing can not be done.
2.2.7 System Info
Press “SYSTEM INFO” to go to system information interface.
This page include of the language selection and the version of the controller.