User still can selet the “check follow up ” to be “use delay” and the “check follow”
to be “using trigger”.
The first operation should be careful. The following step should be noticed:
1) If the drive is servo drive, please set the parameters correctly according to the
operating manual of the servo drive.
2)
Then power on the distance controller, go to the “MENU”
“Setting”. Configure
the parameters correctly.
3) To check the limit switch is good or not. User can trigger the limit manually. If it
work well , the information of up limit trigger or down limit trigger will be
displayed in the screen. That means the limits are working well.
If the polarity of the limit is wrong, please check and modify the polarity of the
limit in the menu.
Then check the crash alarm is good or not. Just move the laser head or the work
piece to keep they touch each other. If there are crash alarm information
displays in the screen, which means the crash alarm is ok.
4) Press
, check the moving direction of the laser head
,
if the
direction is not the desired direction, then modify the
“motor polarity”.
5) Calibration. If the calibration result is good, then save the data.
6) Press
“trace off”
,
the button will changed into green and the text will change into
“trace on”. Press the “.” on the operating panel of the cutting system. The laser
head will tracing down to the work piece and enter the tracing mode. Press “.”
again, the laser head will rise to a certain position.
7) If all the steps is ok, that means the distance controller work well.