LFS-PM Series Live Focus System Operating Manual
13
Metal
Air
High-pressure
The Third Program:3 relay wiring
Parameter setting: If punching is low pressure gas and cutting is high
pressure gas.
When cutting Non-metal (Follow OFF), LFS will control the Air channel outlet
all the time.
In the mode of cutting metal (Follow ON), LFS will control the Low-pressure
gas channel outlet When punching and control High-pressure gas outlet
when cutting.
High-pressure control
solenoid valve
Low-pressure control
solenoid valve
Air control
solenoid valve
+24V
CN7
3
Air
CN7
2
Blow_L
CN7
1 BloW_H
Cutting type Gas channel of punching Gas channel of cutting
Non-metal
Air
Metal
Low-pressure
High-pressure
3.1.1 Sensor Interface
This interface is to connect the amplifier and distance controller.
When installing the amplifier, the shield of the amplifier should be have good
conduction with the laser head (sensor and nozzle). There a wiring terminal on the shield
of the amplifier. User can connect the terminal to the laser head. The metal sheet should
still have a good conduction with the machine. Or the capacity sensor will not work
normally.