LFS-PM Series Live Focus System Operating Manual
5
When cutting non-metal, this para is invalid.
Height Para
Rise Height
The rising height for laser head during jump motion.
Alarm Height
When the alarm triggered, the laser head is on the
stop height.
Standby Height
When the cutting task is finished, the laser head is on
the position.
Focus Position
The distance between the nozzle and the work piece.
Reset Height
When reset the laser head, the laser head will trigger
the limit switch and move reversely for this distance.
Max Follow
Error
During a close control, the error between the actual
position and referenced poison should never beyond
the value. If that happened, system protection will be
executed and generate the alarm of following error
over limit.
Increment
Height
The height of nozzle and plate when increment
punching.
Speed Para
Rise Speed
Rising speed.
Follow Speed
The maximum tracing speed.
Reset Speed
Laser head reset speed.
Manual Speed
High
The manual fast speed.
Manual Speed
Low
The manual slow speed.
Increment
Speed
The speed of increment punching when cutting head
go down.
Machine
Para
Direction
Polarity
Set the rotation of the motor.
Acceleration
Motion acceleration.
Screw Pitch
Screw pitch.
Circle Pulse
Number
When the motor rotate one round, the number of
control pulse should sent to the motor drive.
Other Para
Enable Power
On Reset
Enable or disable the reset when power on.
Enable Crash
Protect
If the crash alarm is enabled, when the laser head
has touched the work piece for a certain time(over
the filter time), system will rise up the laser head and
stop the motion of the cutting system.
If it is disabled, the crash alarm will be neglected.
Limit Polarity
Set the sense of the limit switch. If a NPN limit switch
is installed, user should set the polarity to be
negative. If it is PNP, the polarity should be set to
positive.
Enable Limit
If the limit protection is enabled, when the limit is