LFS-PM Series Live Focus System Operating Manual
6
triggered, the motion protection will take affect such
as rising the laser head and stop motion.
2.2.3 Parameter Management
Parameters management is used to save and restore the parameters of the distance
controller. Not everybody can operate this function. There are passwords for user to
manage this function. When user has configured all the parameters correctly, then these
parameters can be set to be default. So if the parameters have been changed, user can
restore the right parameters from the default. We suggest that user must save the correct
parameters to be default when all the parameters have been tuned correctly.
2.2.4 Alarm Information
On the main menu, press “ALARM INFO” to go to “ALARM INFO” interface.
User can check the alarm information. The information include of the alarm time and
alarm source. The maximum records are
9 records that is saved. Press the “Clear”, all the
information is cleared.
User still can press “Page Up” or “Page Down” to check the
information.