22 Installation
KP Series
Bosch Security Systems, Inc.
Technical Manual
F.01U.304.914
Rev. 05
KP-5032/5032PB Installation
IMPORTANT:
If you plan to use the Power Supply Mounting Bracket, we recommend you install the mounting bracket
before cabling the keypanel. For information on different power supply mounting options, see “Power
Supply Mounting Options” on page 297.
IMPORTANT:
When an OEI-2 power supply is used on a KP-Series keypanel, the following warning icon blinks to
display the wrong power supply is being used. No damage occurs.
To
install the KP-5032/5032PB
, do the following:
1.
On the rear panel, plug the
24 VDC power connector (A)
of the power supply into the power connector on the back
panel of the unit.
2.
Connect an
RJ-12
or
RJ-45 (568B or USOC) cable
(B)
with RTS cabling to the J8 FRAME connector.
OR
Connect a
CAT-5e cable (C)
to either J11 or J12 ETHERNET connector.
NOTE:
•
If using the optional J13 fiber connector, connect a
fiber connector (D)
to the OPTICAL fiber
connector on the rear panel.
•
The KP-Series panels can have both AIO and Ethernet connected simultaneously, an the user can switch
between the connections using the menus.
3.
Once the unit is cabled, plug the
power supply power cord
into the wall outlet or a power strip.
FIGURE 4.
KP-5032 Installation
Summary of Contents for KP-4016
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 4 KP Series...
Page 8: ...Bosch Security Systems Inc Technical Manual 8 KP Series Rev 05 F 01U 304 914...
Page 12: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 12 KP Series...
Page 160: ...160 Basic Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Page 292: ...292 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Page 302: ...302 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...