background image

 

OPERATING GUIDE for your 

 

GEM-RP4C and GEM-RP4RFC KEYPAD 

© NAPCO 2006 

ARM

ED

 

COMP UT ERIZED SECURITY SYST EM 

STA

TUS

 

GEM INI 

 

A   1   2   3  

 

B   4   5   6  

 

C   7   8   9   0  

 

 

 

INTERIOR 

96 

   

NEXT / YES 

PRIOR / NO 

AREA 

96 

 

 

INTERIOR 

 

 

 

 

BYPASS 

 

OI278A  8/06 

Summary of Contents for Gemini GEM-RP4C

Page 1: ...ING GUIDE for your GEM RP4C and GEM RP4RFC KEYPAD NAPCO 2006 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI A 1 2 3 B 4 5 6 C 7 8 9 0 E F G J INTERIOR 96 NEXT YES PRIOR NO AREA 96INTERIOR BYPASS OI2...

Page 2: ...ighest industry standards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in b...

Page 3: ...S 21 PROGRAMMING USER CODES 22 GLOSSARY 24 SYSTEM TROUBLE ERROR CODES 27 TROUBLESHOOTING 31 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL __________________ CENTRAL STATION ________...

Page 4: ...NDICATORS ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI A 1 2 3 B 4 5 6 C 7 8 9 0 E F G J INTERIOR 96 1 2 3 4 5 6 7 12 8 9 10 11 13 NEXT YES PRIOR NO AREA 96 RESET INTERIOR FIRE INSTANT CANCELLED T...

Page 5: ...Keys 1 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or selected function to be executed INTERIOR Button 1 Bypasses all Interior Zones simultaneously to all...

Page 6: ...dicating an error Re enter your code 3 Leave the premises Leave through the exit door before the exit time expires Priority Arming If you attempt to arm the system with a faulted Zone a 3 second tone...

Page 7: ...s may be armed while others remain disarmed Manager s Mode The Manager s Mode allows the user to arm disarm other areas in a partitioned system To arm a different area 1 Press the numerical key repres...

Page 8: ...d for Automatic Interior Bypass which allows it to recognize that you have armed the system and remained in the house prompting it to automatically adjust the interior protection accordingly If you ar...

Page 9: ...Emergency programmed YES NO Easy Exit Optional Easy Exit programmed YES NO Your system may have been programmed for Easy Exit which allows a user to exit the premises while the system is armed By acti...

Page 10: ...call authorities from a neighbor s phone To silence an audible alarm 1 Enter your code and press J After the system is disarmed the window will continue to display the number s of the zone s violated...

Page 11: ...icator light will be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad within about 10 seconds Fire Zone Trouble T...

Page 12: ...with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not s...

Page 13: ...13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan...

Page 14: ...es because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen...

Page 15: ...no activity is detected for longer than one minute 1 Display Zone Status Displays the zone number of zones that are not secured Press the NEXT and PRIOR Buttons as displayed on screen to scroll fault...

Page 16: ...l zones required for GEM P3200 9600 panels GEM P816 1632 panels will auto scroll 7 Activate Chime The Chime Mode will sound a tone at the keypad when the programmed zone is opened while disarmed To de...

Page 17: ...set Sensor Watch Failure and press D If you cannot correct the problem call for service Note This function available with GEM P9600 and GEM P3200 control panels only With the GEM P816 1632 panels Sens...

Page 18: ...ally after a delay period of 1 to 4 hours To Delay Arm the system With Function 16 in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by D At the end of this 1 4 hour Delay...

Page 19: ...to turn the displayed group on or off press NEXT E to proceed to the next group or PRIOR F to scroll back to the previous group Press C when done Relay Group 01 ____________________________________ Re...

Page 20: ...econds at your option by consulting with your in staller Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restore...

Page 21: ...ntral station acknowledges receipt ringback exit delay will start If ringback is not heard within about 30 seconds a communication problem may exist call for service Function 11 Start Exit Time may th...

Page 22: ...ll beep while in the User Program Mode Programming Reprogramming a User Code 1 Press A followed by the the 2 digits of the user number to be programmed Example for User 4 enter 04 2 Press A followed b...

Page 23: ...e Notes If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt which is No 1 ask your installer While in Program Mode the ARMED and STATUS...

Page 24: ...rough Managers Mode Arming Disarming Turning the system on off by entering your code at the keypad then pressing J Battery Backup power source in the control panel enclosure to provide protection in t...

Page 25: ...port A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless systems only Weak transmitter battery RF Supervisory Wi...

Page 26: ...ce through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including space protection devices interior doors et...

Page 27: ...ng company for service as soon as possible Trouble Indication System Trouble Condition Action E 01 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is p...

Page 28: ...B The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with t...

Page 29: ...service E 15 NN RF Transmitter Tamper Wireless Transmitter Tamper Cover removed NN Transmitter Number Call installing company for service E 16 NN Wireless Receiver Jam A problem has been detected with...

Page 30: ...talling company for service E 24 Service Message The system is in need of a preventive maintenance service call E 27 00 Printer Failure Call installing company for service E 39 00 Receiver Capacity Er...

Page 31: ...the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 27 The Fire Alarm is sounding and...

Page 32: ...any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system ma...

Reviews: