25
Operation Status Display LEDs
LED
Content
ON
OFF
Flicker
A
Indicates
Pulse Output
signal A *1
Pulse/ Sign Output
method setting
-
Stop
Pulse Output
CW/ CCW Output
method setting
-
Stop
(Forward Rotation)
Pulse Output
(Forward
Rotation)
B
Indicates
Pulse Output
signal *1
Pulse/ Sign Output
method setting
Reverse
Rotation
direction
Command
Forward Rotation
direction
Command
-
CW/ CCW Output
method setting
-
Stop
(Reverse Rotation)
Pulse Output
(Reverse
Rotation)
PA
Indicates Pulse Generator Signal
Input *3
Indicates the Input status of Pulse Generator Input
signal A.
PB
Indicates Pulse Generator Signal
Input *3
Indicates the Input status of Pulse Generator Input
signal B.
Z
Indicates the input status of zero
point input *2
ON
OFF
-
D
Indicates the states of Near-zero Point
*2
ON
OFF
-
CL
Indicates Counter Clear Signal
Output
Output ON
Output OFF
-
ER
Indicates that a Wrong Setting Error
occurred
Setting value
error
Setting value is
correct
-
(*1): The pulse output signal display LEDs (A and B) blink at the output frequency (speed). For this reason,
they may appear to light steadily at high-speed output.
(*2): The near home (D) and home input (Z) LEDs light when the respective input becomes valid. The input
valid logic is specified using the control codes in the program.(In the manual,"Z" is described as
"ZSG",and "D" is described as "DOG".)
(*3): Pulse input signal (PA) and (PB) display the pulse signal input status.
Summary of Contents for NX-POSI1
Page 1: ...Catalog Number s NX70 POSIx NX POSIx NX70 700 Position User Manual ...
Page 6: ...6 ...
Page 14: ...14 ...
Page 22: ...22 ...
Page 38: ...38 ...
Page 64: ...64 ...
Page 79: ...79 Program ...
Page 82: ...82 Program ...
Page 106: ...106 Pulse output diagram ...
Page 107: ...107 Sample Program ...
Page 110: ...110 ...
Page 123: ...123 Action of the I O Flag Before and After a Home Return Operation Return Operation ...
Page 132: ...132 ...
Page 147: ...147 Pulse output diagram Deceleration stop operation In progress stop ...
Page 148: ...148 Forced stop operation Emergency stop Overrun ...
Page 158: ...158 ...
Page 170: ...170 ...
Page 178: ...178 Oriental Motor Co Ltd UPK W Series Open collector output stepping drive connection ...
Page 179: ...179 NX700 PLC External Dimensions 1 System Dimensions mm Motherboard Installation Diagram mm ...
Page 180: ...180 2 CPU I O Analog Unit Dimensions mm 3 Special Unit Dimensions mm ...
Page 183: ...183 Program ...
Page 187: ...187 Program ...
Page 188: ...188 ...
Page 194: ...Publication NX700 UM007A PositionA EN December 2010 ...
Page 195: ......
Page 196: ...Copyright 2010 RS Automation Co Ltd All rights reserved ...