Open collector output
This is one output format used in pulse output signal circuits, enabling to make
connections in accordance with the voltage of the power supply being used by
connecting an external resistance. This is used when connecting a driver that does
not have line driver input, such as a stepping motor.
JOG operation
This refers to an operation in which the motor is rotated only while operation
commands are being input. This is used to forcibly rotate the motor using input
from an external switch, for instance when to make adjustments. Depending on the
circumstances, this can also be applied to unlimited feeding in some cases.
Deceleration stop
This is a function that interrupts the operation in progress, slows the rotation and
brings it to a stop. This is used to stop an operation halfway.
JOG positioning operation
This refers to an operation to transfer a JOG operation to a positioning operation by
an input from the external switch.
Positioning control start input (Timing input)
This is a JOG positioning operation input to transfer a JOG operation to a
positioning operation. The pulse count settings can be output after the external
switch input.
Over limit input (+), Over limit input (-)
This is an input to set a limit the motor movement. Over limit input (+) is the
maximum limit and Over limit input(-) is the minimum limit.
Home return, Home search
The reference position for positioning is called a Home position and an operation to
travel to a Home position is called Home return. The home position should be set in
advance. This operation moves to the home position and its coordinate is set to be
0.
Home search automatically reverses the motor rotation when Over limit input(+) or
Over limit input (-) is input and searches the home position or the near home
position to return to the home position automatically.
Forced stop
This is a function which interrupts the operation in progress, and stops it
immediately. It is used to initiate an emergency stop using anexternal switch, and to
initiate a temporary stop through an overrun.
Summary of Contents for NX-POSI1
Page 1: ...Catalog Number s NX70 POSIx NX POSIx NX70 700 Position User Manual ...
Page 6: ...6 ...
Page 14: ...14 ...
Page 22: ...22 ...
Page 38: ...38 ...
Page 64: ...64 ...
Page 79: ...79 Program ...
Page 82: ...82 Program ...
Page 106: ...106 Pulse output diagram ...
Page 107: ...107 Sample Program ...
Page 110: ...110 ...
Page 123: ...123 Action of the I O Flag Before and After a Home Return Operation Return Operation ...
Page 132: ...132 ...
Page 147: ...147 Pulse output diagram Deceleration stop operation In progress stop ...
Page 148: ...148 Forced stop operation Emergency stop Overrun ...
Page 158: ...158 ...
Page 170: ...170 ...
Page 178: ...178 Oriental Motor Co Ltd UPK W Series Open collector output stepping drive connection ...
Page 179: ...179 NX700 PLC External Dimensions 1 System Dimensions mm Motherboard Installation Diagram mm ...
Page 180: ...180 2 CPU I O Analog Unit Dimensions mm 3 Special Unit Dimensions mm ...
Page 183: ...183 Program ...
Page 187: ...187 Program ...
Page 188: ...188 ...
Page 194: ...Publication NX700 UM007A PositionA EN December 2010 ...
Page 195: ......
Page 196: ...Copyright 2010 RS Automation Co Ltd All rights reserved ...