16
Standing Pilot Ignition System
This system includes millivolt control valve, standing
pilot, thermopile/thermocouple flame sensor, and
piezo ignitor.
WARNING
110-120 VAC MUST NEVER BE
CONNECTED TO A CONTROL VALVE
IN A MILLIVOLT SYSTEM.
Direct Spark Ignition (DSI) System
The DSI system includes a 120V control valve,
electronic module, and spark ignitor/flame sensor.
WARNING: CONTINUOUS 110-120 VAC
SERVICE MUST BE WIRED DIRECTLY
TO THE FIREPLACE JUNCTION BOX
IN A DSI SYSTEM.
Step 5
Positioning,
Leveling, and
Securing the
Fireplace.
1. Place the fireplace
into position.
2. Level the fireplace
from side to side and
from front to back.
3. Shim the fireplace with
non-combustible
material, such as
sheet metal, as
necessary.
4. Secure the fireplace
to the framing by
nailing or screwing
using the nailing tabs.
Figure 9. Proper Positioning, Leveling, and
Securing of a Fireplace
Step 6
The Gas Control
Systems
WARNING
THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Two types of gas control systems are used with these
models:
Standing Pilot Ignition
and
Direct Spark
Ignition (DSI).
The diagram below shows how to properly position,
level, and secure the fireplace.
WARNING:
To ensure proper
clearances, the front
framing header must
be installed on its
narrow edge and to
the front of the
frame.
!
!
!