background image

1

                      LUNA 

700- 1000-1150-1300-1600-1900 H 

                GOLD GAS

                    INSTRUCTION FOR INSTALLATION AND USE

Passion for fire

English 06-2012

Summary of Contents for LUNA 700H

Page 1: ...1 LUNA 700 1000 1150 1300 1600 1900 H GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire English 06 2012...

Page 2: ...L L AT I O N I N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R W...

Page 3: ...E CHIMNEY 8 13 5 INSULATION AND FINISHING 13 6 CONVECTION CURRENT 14 15 16 7 MOUNTING A 3 SIDED FRAME 17 8 POSITIONING THE LOGS DIAMOND SAPPHIRE AND WHITE PEBBLES 18 1000H 19 20 1150H 21 22 1300H 23 2...

Page 4: ...1600 1900H GOLD GAS 4 OPEN CLOSING KEY IF SOME DUST OR WASTE IS SEEN ON THE WINDOW INSIDE AND OUTSIDE CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE CLEANING THE WIN DOW IS THE ONLY MAINTENANCE ACT...

Page 5: ...f your order specifications this appliance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the furnace please check the local...

Page 6: ...pic 2 A min 3 5 cm B 14 5 cm C min 18 cm The stove may not be placed direct ont the floor to allow natural convection The appertures for the air supply IN is situated underneath the appliances Regulat...

Page 7: ...stic 3 1 3 ELECTRICAL CONNECTION These appliances are equiped with a radiographic remote control making an earthened 220V socket necessary You should bear in mind that the appliance must be connectes...

Page 8: ...a roof exit 3m 150 100 Appliance C min C max Restriction HR as from 4m 700 H 1000 H 3 m 18m 60 as from 2 m 75 1150 H 3 m 18m 60 1300 H 3 m 18m 60 1600 H 1900 H 3 m 20m 75 200 130 Appliance C min C max...

Page 9: ...on set USSAN with placing 150 min 100 Appliance C min C max Restriction HR as from 4m 700 H 1000 H 3 m 18m 60 1150 H 3 m 18m 60 1300 H 3 m 18m 60 1600 H 1900 H 3 m 20m 75 200 min 130 Appliance C min C...

Page 10: ...exit A 75 A 200 130 in combination with B 150 100 WITH REDUCTION USVK13 AFTER 90 CURVE ON HORIZONTAL PART FIG 4 Appliance A min 200 130 B min 150 100 B max 150 100 Restriction HR 700 H 1000 H 1 25m w...

Page 11: ...t 75 A 7m 1300 H 1 m wall exit 75 A 6m 1600 H 1 m wall exit 90 A 4m 1900 H 1m wall exit 90 A 2m IMPORTANT BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN NEGATIVE INCLINATION pic 5 IN DIRECTION OF...

Page 12: ...H for each 45 30 15 bend substract 0 5 m horizontaly or add 0 5 m verticaly Pic 5 ROOF EXIT with 90 bends 150 100 WITH REDUCTION USVK13 ON APPLIANCE Aplliance A min B max C min A B C max 700 1000 H 1...

Page 13: ...working check the tightness of the gas pipe and the smoke pipe Once you have checked everything you can perform the final insula ting and finishing operations The built in part of the furnace tends t...

Page 14: ...some grids give off more heat than others and seeing that a hot air pipe functions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even more...

Page 15: ...GOLD GAS 15 Design Grid outlet with 2 connections OUTLET CONVECTION INLET CONVECTION OUTLET CONVECTION Inlet Grid convection air Inlet Grid convection air Design Grid outlet with 2 connections 2 dm 4...

Page 16: ...ES THE STOVE MAY NOT BE PLACED DIRECT ON THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR WTHOUT THE FEETS THIS TO ALLOW NATURAL CONVECTION THE APPERTURES FOR THE AIR SUPPLY ARE SITUATED UNDERNEATH THE...

Page 17: ...e 3 5cm an upper and 2 sideframes see pic 2 Before mounting the 3 sided frame remove 4 sided frame lower piece by lift it carefully up Pull out the upper frame and in second way the left and right sid...

Page 18: ...has cooled down Move the window to the front by pulling it The window tips open at 45 Arrange the materials supplied In accordance with your order you will have either a set of logs diamond sapphire...

Page 19: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 19 1 2 3 4 5 6 7 8 9 5 6 7 8 9 1 2 4 3 LUNA 1000 H GAS...

Page 20: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 20 LUNA 1000 H GAS...

Page 21: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 21 1 2 4 3 5 6 7 8 9 5 6 7 8 9 1 2 4 3 LUNA 1150 H GAS...

Page 22: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 22 LUNA 1150 H GAS...

Page 23: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 23 1 2 3 4 5 6 7 8 9 5 6 7 9 1 2 4 3 8 10 11 12 10 11 12 LUNA 1300 H GAS...

Page 24: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 24 LUNA 1300 H GAS...

Page 25: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 25 1 2 3 4 5 6 7 8 9 5 6 7 9 1 2 4 3 8 10 11 12 10 13 13 11 12 LUNA 1600 H GAS...

Page 26: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 26 LUNA 1600 H GAS...

Page 27: ...s broken or cracked the appliance must not be used until the window has been replaced Contact your M Design reseller 10 SAFETY ADVICE AND MAINTENANCE Have your furnace inspected once a year by a quali...

Page 28: ...onsumption 12 USING THE MANUAL CONTROL BLACK BOX On the user interface a potentiometer is connected This one will be used only when the remote control is broken DON T USE THE POTENTIOMETER SIMULTANIOU...

Page 29: ...C 91 Inlet pressure mbar 25 20 30 37 50 28 30 Burner pressure mbar 24 2 19 3 29 4 36 2 36 2 28 4 Consumption m 3 h 0 870 0 789 0 264 0 299 0 299 0 226 Injector burner 6 x 0 85 6 x 0 85 6 x 0 6 6 x 0...

Page 30: ...re mbar 25 20 30 37 50 28 30 Burner pressure mbar 23 3 19 1 27 9 34 5 34 5 28 4 Consumption m 3 h 0 985 0 868 0 258 0 286 0 286 0 286 Injector burner 6 x 1 6 x 0 95 6 x 0 55 6 x 0 55 6 x 0 55 6 x 0 55...

Page 31: ...mbar 25 20 30 37 50 28 30 Burner pressure mbar 24 19 2 29 2 36 1 36 1 28 2 Consumption m 3 h 1 132 1 026 0 344 0 389 0 389 0 295 Injector burner 6 x 1 10 6 x 1 10 6 x 0 65 6 x 0 65 6 x 0 65 6 x 0 65 I...

Page 32: ...mbar 25 20 30 37 50 28 30 Burner pressure mbar 23 18 9 28 9 35 5 35 5 27 9 Consumption m 3 h 1 316 1 217 0 315 0 36 0 360 0 273 Injector burner 6 x 1 25 6 x 1 25 6 x 0 65 6 x 0 65 6 x 0 65 6 x 0 65 I...

Page 33: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 33 LUNA 700 H GOLD gas connection gas on the left side...

Page 34: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 34 LUNA 1000 H GOLD gas connection gas on the left side...

Page 35: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 35 LUNA 1150 H GOLD gas connection gas on the left side...

Page 36: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 36 LUNA 1300 H GOLD gas connection gas on the left side...

Page 37: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 37 LUNA 1600 H GOLD gas connection gas on the left side...

Page 38: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 38 connection gas on the left side LUNA 1900 H GOLD gas...

Page 39: ...ame above window 4 mm thickness frame 2 mm gap between frame and maconery Apperture to make L X 4mm 4mm 2mm 2mm H Y 2mm Connecting Flex tubes 1000H 1150H 1300H 2x obliged 1600H 4 x obliged M i n i m u...

Page 40: ...ded frame Two flexible tubes can be connected to one design grid 2 connections Connecting Flex tubes 1000H 1150H 1300H 2x obliged 1600H 4 x obliged 4 sided frame 3 5 7 or 10 cm X inside measurement fr...

Page 41: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 41 4 sided frame X 3 5 cm X 7 cm X 10 5 cm onderlat baguette 35 70 105 Z X DETAIL Z 4th side frame...

Page 42: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 42 14 SPARE PARTS...

Page 43: ...rd party including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the furnace without our consent In cases where the buyer cannot show his her warran...

Page 44: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 700 1000 1150 1300 1600 1900H GOLD GAS 44 15 CE CERTIFICATION...

Reviews: