background image

4001955-12

© 2011, Miles Industries Ltd. All rights reserved.

H4 S

ERIES

HOT GLASS

 WILL 

CAUSE BURNS.

DO NOT TOUCH

 GLASS 

UNTIL COOLED.

NEVER

 ALLOW CHILDREN 

TO TOUCH GLASS.

WARNING: If the information in these 
instructions is not followed exactly, a fi re 
or explosion may result causing property 
damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light the appliance.
• Do not touch any electrical switch; do not 

use any phone in your building.

• Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 
supplier’s instructions.

• If you cannot reach your gas supplier, call 

the fi re department.

This appliance is only for use with the type 
of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases, unless a certifi ed kit is used.

This appliance is a domestic room-heating 
appliance. It must not be used for any other 
purposes such as drying clothes, etc.

This appliance is suitable for installation in a 
bedroom or bed sitting room.

Manufactured by

MILES INDUSTRIES LTD., 

British Columbia, Canada

www.valor

fi

 replaces.com

Installation & Operating Instructions

Do not store or use gasoline or other 
fl ammable vapors and liquids in the vicinity 
of this or any other appliance.

Installation and service must be performed 
by a qualifi ed installer, service agency or the 
gas supplier.

This appliance may be installed in an 
after-market permanently located, 
manufactured (mobile) home where not 
prohibited by local codes.

Model 650ILN (Natural Gas)

Model 650ILP (Propane)

Direct Vent Gas Fireplace Heater

INSTALLER: Leave this manual 
with the appliance.
CONSUMER: Retain this manual 
for future reference.

Massachusetts: The piping and fi nal 
gas connection must be performed by a 
licensed plumber or gas fi tter in the State of 
Massachusetts. Also, see Carbon Monoxide 
Detector requirements under “Safety and 
Warning Information” on page 5.

Please read this manual BEFORE 
installing and operating this 
appliance.

Summary of Contents for 650ILN

Page 1: ...any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www valorfirepla...

Page 2: ...by a qualified dealer Each Valor fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name _______________________...

Page 3: ...22 Liner Panels Installation 23 Ceramic Logs Installation 24 Window Refitting Baffle Installation 25 Wall Switch Kit Installation 26 Remote Control Initial Set up 27 Operation Check Aeration Settings...

Page 4: ...OBSTRUCT the flow of combustion and ventilation air Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation Due to the high temperature the appliance s...

Page 5: ...ch additional level of the dwelling building or structure served by the side wall horizontal vented gas fueled equipment It shall be the responsibility of the property owner to secure the services of...

Page 6: ...facturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirement...

Page 7: ...al and or local authorities having jurisdiction Model 650ILN 650ILP Gas Natural Propane Altitude Ft 0 4 500 Input Max Btu h 24 000 24 000 Input Min Btu h 6 500 13 000 Manifold pressure in w c 3 95 10...

Page 8: ...le from top to rear outlet Framing See Framing section Remote Handset Wall Holder Wall Finish May be combustible material NOTE Finished wall surface including tiles etc MUST be minimum 3 4 19 mm set b...

Page 9: ...406 mm 26 3 4 679 mm 38 5 8 981 mm 32 3 16 817 mm 29 3 4 756 mm 30 3 4 781 mm 3 76 mm min To side wall from inner frame in front of the appliance 8 1 4 210 mm From finished wall surface to top vent MI...

Page 10: ...ear vent with rise MINIMUM 1 2 13 mm space between bottom of backing plate and surface of hearth or floor finish in front for air flow Combustible framing allowed beneath fireplace When the appliance...

Page 11: ...ess A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation 10 254 mm 10 254 mm Align the vent center to the center of the...

Page 12: ...WALL THIMBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH 817VAK 817VAK PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION Typical Co Axial...

Page 13: ...ling the joints between the outer vent tube and the inner and outer wall plates We recommend the use of a high quality polyurethane sealant Co Axial Venting Rear Vent with No Vertical Rise The horizon...

Page 14: ...mended to prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18...

Page 15: ...n connecting the 551DVK terminal directly to the appliance Max 24 before elbow Min 12 rise 45 elbow directly on flue collar is allowed with min 6 pipe between elbows 1 min all around vertical pipe 3 m...

Page 16: ...ows or equivalent 2 x 45 degrees 90 degrees can be used 5 Each 90 degrees elbow installed on the horizontal plane is equivalent to a 3 feet horizontal pipe therefore 3 feet must be subtracted from all...

Page 17: ...ance with the dimensions shown in the Co Axial Venting section of this manual Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small h...

Page 18: ...solid fuel burning fireplace and chimney The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Requires 556CLA Co Axial to Co Linear Appliance Adapter...

Page 19: ...and seal inside the rear outlet opening Secure the inner collar with 8 screws 5 Fit the outer collar over inner collar Loosely fit the 12 screws Place the adapter 817VAK or Valor terminal kit 551DVK o...

Page 20: ...Bend the 12 inch stand off and fix it to the appliance case with the two screws just removed as indicated 5 Place the appliance in position in the framing 6 Secure the appliance to the studs Note The...

Page 21: ...each type of installation To fit the restrictors loosen the two center screws of the left and right inlet ports Place the restrictor assembly under the screw heads and tighten the center screws To set...

Page 22: ...the gas supply connection to the appliance Pressure test the supply line for leaks The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pre...

Page 23: ...as forward as possible against the left edge of the firebox 3 Hold the right hand side panel at an angle and insert its bottom edge inside the firebox Rotate the panel to a vertical position ensuring...

Page 24: ...ther end in the crook of the front right log 5 Identify the middle cross log It does not have a hole underneath Place its narrow end on the flat depression in the rear log next to the right cross log...

Page 25: ...ing them through 90 degrees 3 Hook the window baffle to the top of the window frame Be careful not to hook it onto the firebox frame see images below 4 Grab the top of the window and baffle and pull t...

Page 26: ...Do not force it or damage the pins on the receiver box 4 Take the switch wire and plug it into the receiver s connection slot as indicated the other slot should already be fitted with the valve s wir...

Page 27: ...ocks and window installed Increasing aeration will cause the flames to appear more transparent and blue showing more ceramic rock glow Decreasing aeration will cause the flames to appear more yellow o...

Page 28: ...te film If the film is left for a longer period of time it will bake on It is then much harder if not impossible to remove NEVER use an abrasive cleaner on the ceramic glass Any abrasion of the surfac...

Page 29: ...the window frame Be careful not to hook it onto the firebox frame see image below and page 25 4 Grab the top of the window and baffle and pull them forward and release to check that the window opens...

Page 30: ...r and pull it out from its location 2 Slide and remove the receiver cover 3 Replace the 4 AA batteries 4 Replace the cover 5 Put the receiver back in its position pushing it in so it attaches to the V...

Page 31: ...tor turns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and...

Page 32: ...pressing either the or buttons Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in...

Page 33: ...efore you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go...

Page 34: ...here natural gas was not available at the time of initial installation 650PGK Propane Gas Conversion Kit For conversion from natural gas to propane gas Hearth Gate optional Hearth gates such as Kidco...

Page 35: ...uding near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION MAN knob 2 in ON position Ensure Flame...

Page 36: ...36 36 Wiring Diagram Wall Switch Kit Connector Red Yellow GV60 Wiring Diagram...

Page 37: ...36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 TM CFAA3 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA G...

Page 38: ...B SV4B Flat Roof Flashing 46DVA FF TF 4F SV4F 559FSK Masonry Flashing TF 4MF Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM Storm Collar 46DVA SC 4DT SC TM SC SV4AC Decorative...

Page 39: ...on for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not...

Page 40: ...Burner plate 4001966 33 Gaskets module plate sides 2 3000399 34 Gaskets module plate front back 3000400 35 Valve mounting bracket 4000141 36 Thermocurrent interruptor 4001037 Key Description Part no 3...

Page 41: ...41 41 60 41a NG LPG 15 17 22 23 24 25 26 18 19 20 21 16 36 35 4 4a 34 3 3 9 14 2 8 13 50 55 56 57 58 59 51 52 53 54 1 5 6 7 28 27 33 32 29 30 31 43 49 48 46 45 44 38 37 40 41 47 42 39 12a 12b 11a 11b...

Page 42: ...natural gas LPG propane Serial No Front Trim code description e g 660LSV Landscape Surround Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email Address Sto...

Page 43: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...