Example :
Position 1 = 5 %
Capacity I = 2500 kg/hour
Cap II - p1 =
5 x 2500
100
−
5
= 131kg/
hour
4. DETERMINE THE CORRECT FREQUENCIES
Use the graph Capacity FA II in function of the frequency.
FIGURE 3.
F1
F2
F3
F
(Hz)
Cap
Kg/h
Cap II - P1
P2
P3
P4
P5
P6
F6
F5
F4
Min. 10 Hz
Max. 130 Hz
P7
P0
F7
5. HOW TO PROGRAM THIS ON THE FREQUENCY REGULATOR ?
You must program the following parameters :
P1001 = F1
P1002 = F2
P1003 = F3
P1004 = F4
P1005 = F5
P1006 = F6
P1007 = F7
First press the
P
button.
Go to parameter P1001 with
Press
P
Change the value with
and
(value = frequency, for example 12 Hz)
Press
P
to confirm that value.
Go to parameter P1002 with
Repeat the above steps.
Same procedure for the other parameters P1003, P1004, P1006 and P1007.
After P1007 you go to P000 with
Press
P
to quit the programme.
Summary of Contents for FLEX-AUGER FA 125
Page 6: ......
Page 11: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Page 12: ...FLEX AUGER INSTRUCTIONS FOR THE USER ROXELL 031 0516 I 2 ...
Page 24: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 2 FIGURE 1 GENERAL VIEW ...
Page 86: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 64 GENERAL LAY OUT OVERHEAD SYSTEM FIGURE 5 A B C ...
Page 96: ......
Page 97: ...III 1 PART III INSTALLATION INSTRUCTIONS ...
Page 98: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 ...
Page 100: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 FIGURE 1 GENERAL VIEW ...
Page 166: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 68 FIGURE 135 ...
Page 177: ......